
CSA Z276.2:25
CSA Z276.2:25 – Liquefied natural gas (LNG) — Floating near-shoreline production, storage, and handling
CDN $472.00
Liquefied natural gas (LNG) — Floating near-shoreline production, storage, and handling
Description
Thanks to the financial contribution of the Western Regulators Forum (WRF), CSA Group is providing the CSA Petroleum and Natural Gas standards in a downloadable PDF format for no fee to Canadian customers only ( Click for more detail) . If you are not in Canada, please reach out to one of the following licensed CSA Group resellers to purchase these standards or contact your local reseller: • Accuris: ( https://store.accuristech.com ) • Intertek Inform: ( https://www.intertekinform.com/ ) Preface This is the first edition of CSA Z276.2, Liquefied natural gas (LNG) — Floating near-shoreline production, storage, and handling . It replaces CSA EXP276.2, Design requirements for near-shoreline floating liquefied natural gas (FLNG) facilities, published in December 2020. This Standard outlines minimum requirements for the design of floating near-shore LNG (FLNG) facilities, associated LNG storage components embedded within FLNG facilities, transfer systems, mooring systems, and the modularization and marinization of process equipment. This Standard recognizes the need for a comprehensive and risk-based approach to facility design and layout, and is intended to be used in conjunction with applicable clauses in CSA Z276. This Standard was prepared by the Subcommittee on Liquefied Natural Gas (LNG) — Floating Near-Shoreline Production, Storage, and Handling, under the jurisdiction of the Technical Committee on Liquefied Natural Gas (LNG) — Production, Storage, and Handling, and the Strategic Steering Committee on Liquid and Gaseous Energy Systems, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Application This Standard applies to a) permanently moored floating near-shore facilities used for pre-treatment of natural gas, liquefaction of natural gas, storage of LNG, or offloading of LNG; b) purpose-built floating LNG facilities and repurposed LNG carriers; c) ship-to-shore interfaces (e.g., gas supply and electrical connections); and d) station-keeping systems (e.g., tethering structures and mooring systems). Note: See Figure 1for CSA standards that address minimum standards for onshore LNG facilities, marine structures associated with onshore LNG facilities, and floating near-shoreline LNG facilities. 1.2 Other LNG applications CSA Z276.1 contains additional requirements for LNG loading operations. 1.3 Exclusions This Standard does not apply to a) onshore LNG facilities (see CSA Z276); b) offshore LNG facilities; c) LNG carrier design; d) floating facilities used for the purpose of LNG regasification (i.e., floating storage and regasification units); e) associated marine structures (e.g., piers, wharves, or jetties) (see CSA Z276.1); and f) gravity-based structures. 1.4 Units The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
94
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Thanks to the financial contribution of the Western Regulators Forum (WRF), CSA Group is providing the CSA Petroleum and Natural Gas standards in a downloadable PDF format for no fee to Canadian customers only ( Click for more detail) . If you are not in Canada, please reach out to one of the following licensed CSA Group resellers to purchase these standards or contact your local reseller: • Accuris: ( https://store.accuristech.com ) • Intertek Inform: ( https://www.intertekinform.com/ ) Preface This is the first edition of CSA Z276.2, Liquefied natural gas (LNG) — Floating near-shoreline production, storage, and handling . It replaces CSA EXP276.2, Design requirements for near-shoreline floating liquefied natural gas (FLNG) facilities, published in December 2020. This Standard outlines minimum requirements for the design of floating near-shore LNG (FLNG) facilities, associated LNG storage components embedded within FLNG facilities, transfer systems, mooring systems, and the modularization and marinization of process equipment. This Standard recognizes the need for a comprehensive and risk-based approach to facility design and layout, and is intended to be used in conjunction with applicable clauses in CSA Z276. This Standard was prepared by the Subcommittee on Liquefied Natural Gas (LNG) — Floating Near-Shoreline Production, Storage, and Handling, under the jurisdiction of the Technical Committee on Liquefied Natural Gas (LNG) — Production, Storage, and Handling, and the Strategic Steering Committee on Liquid and Gaseous Energy Systems, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Application This Standard applies to a) permanently moored floating near-shore facilities used for pre-treatment of natural gas, liquefaction of natural gas, storage of LNG, or offloading of LNG; b) purpose-built floating LNG facilities and repurposed LNG carriers; c) ship-to-shore interfaces (e.g., gas supply and electrical connections); and d) station-keeping systems (e.g., tethering structures and mooring systems). Note: See Figure 1for CSA standards that address minimum standards for onshore LNG facilities, marine structures associated with onshore LNG facilities, and floating near-shoreline LNG facilities. 1.2 Other LNG applications CSA Z276.1 contains additional requirements for LNG loading operations. 1.3 Exclusions This Standard does not apply to a) onshore LNG facilities (see CSA Z276); b) offshore LNG facilities; c) LNG carrier design; d) floating facilities used for the purpose of LNG regasification (i.e., floating storage and regasification units); e) associated marine structures (e.g., piers, wharves, or jetties) (see CSA Z276.1); and f) gravity-based structures. 1.4 Units The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA N290.2:17 (R2022) – Requirements for emergency core cooling systems of nuclear power plants
CDN $1,243.00 Add to cart -

CSA Z620.2:20 (R2025) – Compressor seal vent gas flow rate testing and recording
CDN $307.00 Add to cart -

CSA N290.3:22 – Requirements for the containment system of nuclear power plants
CDN $1,243.00 Add to cart -

CSA Z276:22 – Liquefied natural gas (LNG) – Production, storage, and handling
CDN $612.00 Add to cart







