
CAN/CSA-Z247-15 (R2025)
CAN/CSA-Z247-15 (R2025) – Damage prevention for the protection of underground infrastructure
CDN $449.00
Damage prevention for the protection of underground infrastructure
Description
Thanks to the financial contribution of the Western Regulators Forum (WRF), CSA Group is providing the CSA Petroleum and Natural Gas standards in a downloadable PDF format for no fee to Canadian customers only ( Click for more detail ). If you are not in Canada, please reach out to one of the following licensed CSA Group resellers to purchase these standards or contact your local reseller: • Accuris: ( https://store.accuristech.com/ ) • Intertek Inform: ( https://www.intertekinform.com/ ) Preface This is the first edition of CSA Z247, Damage prevention for the protection of underground infrastructure. Users of this Standard are reminded that additional and site-specific requirements might be specified by federal, provincial/territorial, or municipal authorities. This Standard should not be considered as a replacement for the requirements contained in any a) applicable federal, provincial/territorial, or municipal statute; or b) regulation, licence, or permit issued pursuant to an applicable statute. Explanatory material and special formatting have been added to clarify the content: an asterisk (*) beside a clause number identifies those clauses for which further information is provided in Annex A. This Standard was prepared by the Technical Committee on Damage Prevention for the Protection of Underground Energy and Utility Networks, under the jurisdiction of the Strategic Steering Committee on Petroleum, Natural Gas, and Industry Systems, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for preventing damage to underground infrastructure. Note: Examples of underground infrastructure include a) oil and gas pipelines; b) electrical and telecommunication cables; and c) water and sewer lines. 1.2 This Standard applies to ground disturbance in proximity to existing, deactivated, abandoned in-place, or reserved for future use underground infrastructure. 1.3 This Standard identifies the damage prevention process and outlines its key elements that, when consistently applied, will prevent and reduce damage to all underground infrastructure and enhance public safety. 1.4* This Standard does not apply to infrastructure that is a) above grade; or Note: Examples of above-grade infrastructure include overhead wires, pole- or tower-mounted devices, and antennas. b) installed below grade for private use on private land, where the landowner is both the excavator and the infrastructure owner. Note: With respect to the above exemptions, this Standard may still provide valuable guidance. The exempted user of this Standard can determine the applicability and suitability of the guidance provided by this Standard. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
36
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Thanks to the financial contribution of the Western Regulators Forum (WRF), CSA Group is providing the CSA Petroleum and Natural Gas standards in a downloadable PDF format for no fee to Canadian customers only ( Click for more detail ). If you are not in Canada, please reach out to one of the following licensed CSA Group resellers to purchase these standards or contact your local reseller: • Accuris: ( https://store.accuristech.com/ ) • Intertek Inform: ( https://www.intertekinform.com/ ) Preface This is the first edition of CSA Z247, Damage prevention for the protection of underground infrastructure. Users of this Standard are reminded that additional and site-specific requirements might be specified by federal, provincial/territorial, or municipal authorities. This Standard should not be considered as a replacement for the requirements contained in any a) applicable federal, provincial/territorial, or municipal statute; or b) regulation, licence, or permit issued pursuant to an applicable statute. Explanatory material and special formatting have been added to clarify the content: an asterisk (*) beside a clause number identifies those clauses for which further information is provided in Annex A. This Standard was prepared by the Technical Committee on Damage Prevention for the Protection of Underground Energy and Utility Networks, under the jurisdiction of the Strategic Steering Committee on Petroleum, Natural Gas, and Industry Systems, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for preventing damage to underground infrastructure. Note: Examples of underground infrastructure include a) oil and gas pipelines; b) electrical and telecommunication cables; and c) water and sewer lines. 1.2 This Standard applies to ground disturbance in proximity to existing, deactivated, abandoned in-place, or reserved for future use underground infrastructure. 1.3 This Standard identifies the damage prevention process and outlines its key elements that, when consistently applied, will prevent and reduce damage to all underground infrastructure and enhance public safety. 1.4* This Standard does not apply to infrastructure that is a) above grade; or Note: Examples of above-grade infrastructure include overhead wires, pole- or tower-mounted devices, and antennas. b) installed below grade for private use on private land, where the landowner is both the excavator and the infrastructure owner. Note: With respect to the above exemptions, this Standard may still provide valuable guidance. The exempted user of this Standard can determine the applicability and suitability of the guidance provided by this Standard. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.








