CAN/CSA-P.11-07 (R2022) – Testing method for measuring efficiency and energy consumption of gas-fired unit heaters
CDN $317.00
Testing method for measuring efficiency and energy consumption of gas-fired unit heaters
Description
Preface This is the first edition of CSA P.11, Testing method for measuring efficiency and energy consumption of gas-fired unit heaters. This Standard specifies requirements for measuring the thermal efficiency, electric power consumption, and power factor of gas-fired unit heaters and references test procedure and thermal efficiency performance requirements specified in ANSI Z83.8/CSA 2.6, Gas unit heaters and gas-fired duct furnaces. CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of Natural Resources Canada (NRCan). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Unit Heaters, under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories and the Strategic Steering Committee on Fuel Burning Equipment, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for measuring the thermal efficiency, electric power consumption, and power factor of gas-fired unit heaters with a maximum input rate of 2 931 kW (10 000 000 Btu/h) or less (including utility heaters with a maximum input rate of 117.2 kW [400 000 Btu/h] or less) constructed of unused parts and materials, for use with (a) natural gas with an inlet pressure of 34.5 kPa (5.0 psi) or less; (b) manufactured gas; (c) mixed gas; (d) liquefied petroleum gases; and (e) liquefied petroleum gas-air mixtures. 1.2 This Standard covers unit heaters designed to be convertible from natural gas to liquefied petroleum gases and vice versa. 1.3 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
27
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of CSA P.11, Testing method for measuring efficiency and energy consumption of gas-fired unit heaters. This Standard specifies requirements for measuring the thermal efficiency, electric power consumption, and power factor of gas-fired unit heaters and references test procedure and thermal efficiency performance requirements specified in ANSI Z83.8/CSA 2.6, Gas unit heaters and gas-fired duct furnaces. CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of Natural Resources Canada (NRCan). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Unit Heaters, under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories and the Strategic Steering Committee on Fuel Burning Equipment, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for measuring the thermal efficiency, electric power consumption, and power factor of gas-fired unit heaters with a maximum input rate of 2 931 kW (10 000 000 Btu/h) or less (including utility heaters with a maximum input rate of 117.2 kW [400 000 Btu/h] or less) constructed of unused parts and materials, for use with (a) natural gas with an inlet pressure of 34.5 kPa (5.0 psi) or less; (b) manufactured gas; (c) mixed gas; (d) liquefied petroleum gases; and (e) liquefied petroleum gas-air mixtures. 1.2 This Standard covers unit heaters designed to be convertible from natural gas to liquefied petroleum gases and vice versa. 1.3 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA Z663:18 (R2023) – Land use planning in the vicinity of pipeline systems
CDN $315.00 Add to cart -

CSA Z245.12:25 – Steel flanges
CDN $409.00 Add to cart -

CSA Z245.20 SERIES:26 – Plant-applied external coatings for steel pipe
CDN $850.00 Add to cart -

CSA Z245.17:26 – Cold bends
CDN $252.00 Add to cart