CSA N299.3:19 (R2025)
CSA N299.3:19 (R2025) – Quality assurance program requirements for the supply of items and services for nuclear power plants, Category 3
CDN $1,243.00
Quality assurance program requirements for the supply of items and services for nuclear power plants, Category 3
Description
Preface This is the second edition of CSA N299.3, Quality assurance program requirements for the supply of items and services for nuclear power plants, Category 3 . It supersedes the previous edition published in 2016. The CSA N299 series of Standards defines quality assurance program requirements for the provision of items and services for nuclear power plants when specified in the contract between the customer and the supplier. The most significant updates to this edition include a) the addition of requirements on dedication in Clause 8; b) the revision of Annex E to provide guidance on counterfeit, fraudulent, and suspect items (CFSIs); c) the addition of Annex F to provide guidance on risk evaluation; and d) the addition of Annex G to provide guidance on records. This Standard has also been restructured and reordered for better readability. Users of this Standard are reminded that civilian nuclear facilities in Canada are subject to the provisions of the Nuclear Safety and Control Act and its Regulations. This Standard was prepared by the Subcommittee on Quality Assurance Program Requirements for Supply of Items and Services for Nuclear Power Plants, under the jurisdiction of the Technical Committee on Management Systems for Nuclear Facilities and the Strategic Steering Committee on Nuclear Standards, and has been formally approved by the Technical Committee. Scope 1.1 1.1.1 This Standard defines minimum requirements for a supplier’s quality assurance program (hereafter referred to as “QA program”) for the supply of items and services to nuclear power plants — Category 3. Notes: 1) This Standard does not include a separate implementation guide; instead, relevant guidance is found throughout the Standard as notes, or within the relevant annex (see Annexes B through G). 2) The requirements in this Standard do not restrict or specify the form suppliers’ programs should take; nor do the mandatory requirements tell how to establish such programs. They only specify what the programs cover. They allow suppliers to determine how their programs should be structured in response to these requirements in order to suit their own situations and objectives. In other words, the onus is on suppliers to develop programs in a consistent and systematic way which will allow customers, recognized qualifying authorities, or regulatory authorities to survey and audit the programs. 3) This Standard may provide guidance for nuclear facilities other than nuclear power plants. The operators of these facilities may determine the applicability and suitability of this Standard. 1.1.2 The QA program is aimed primarily at controlling production and verification processes, and corrective actions that a) ensure items or services conform to specified requirements; and b) readily detect and control the disposition of nonconformances and prevent their recurrence. 1.2 This Standard applies to suppliers and subsuppliers when specified by the customer. Note: Other QA program standards or management system standards may be used provided that the requirements of this Standard are met. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
90
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the second edition of CSA N299.3, Quality assurance program requirements for the supply of items and services for nuclear power plants, Category 3 . It supersedes the previous edition published in 2016. The CSA N299 series of Standards defines quality assurance program requirements for the provision of items and services for nuclear power plants when specified in the contract between the customer and the supplier. The most significant updates to this edition include a) the addition of requirements on dedication in Clause 8; b) the revision of Annex E to provide guidance on counterfeit, fraudulent, and suspect items (CFSIs); c) the addition of Annex F to provide guidance on risk evaluation; and d) the addition of Annex G to provide guidance on records. This Standard has also been restructured and reordered for better readability. Users of this Standard are reminded that civilian nuclear facilities in Canada are subject to the provisions of the Nuclear Safety and Control Act and its Regulations. This Standard was prepared by the Subcommittee on Quality Assurance Program Requirements for Supply of Items and Services for Nuclear Power Plants, under the jurisdiction of the Technical Committee on Management Systems for Nuclear Facilities and the Strategic Steering Committee on Nuclear Standards, and has been formally approved by the Technical Committee. Scope 1.1 1.1.1 This Standard defines minimum requirements for a supplier’s quality assurance program (hereafter referred to as "QA program") for the supply of items and services to nuclear power plants — Category 3. Notes: 1) This Standard does not include a separate implementation guide; instead, relevant guidance is found throughout the Standard as notes, or within the relevant annex (see Annexes B through G). 2) The requirements in this Standard do not restrict or specify the form suppliers’ programs should take; nor do the mandatory requirements tell how to establish such programs. They only specify what the programs cover. They allow suppliers to determine how their programs should be structured in response to these requirements in order to suit their own situations and objectives. In other words, the onus is on suppliers to develop programs in a consistent and systematic way which will allow customers, recognized qualifying authorities, or regulatory authorities to survey and audit the programs. 3) This Standard may provide guidance for nuclear facilities other than nuclear power plants. The operators of these facilities may determine the applicability and suitability of this Standard. 1.1.2 The QA program is aimed primarily at controlling production and verification processes, and corrective actions that a) ensure items or services conform to specified requirements; and b) readily detect and control the disposition of nonconformances and prevent their recurrence. 1.2 This Standard applies to suppliers and subsuppliers when specified by the customer. Note: Other QA program standards or management system standards may be used provided that the requirements of this Standard are met. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA N290.2:17 (R2022) – Requirements for emergency core cooling systems of nuclear power plants
CDN $1,243.00 Add to cart -

CSA N290.0:17 (R2022) – General requirements for safety systems of nuclear power plants
CDN $1,243.00 Add to cart -

CSA Z245.15:25 – Steel valves
CDN $472.00 Add to cart -

CSA Z245.1:26 – Steel pipe
CDN $756.00 Add to cart