Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

N290.0-11 (R2016)/N290.2-11 (R2016) PACKAGE

N290.0-11 (R2016)/N290.2-11 (R2016) PACKAGE – Consists of N290.0-11, General requirements for safety systems of nuclear power plants and N290.2-11, Requirements for emergency core cooling systems of nuclear power plants

CDN $1,243.00

Consists of N290.0-11, General requirements for safety systems of nuclear power plants and N290.2-11, Requirements for emergency core cooling systems of nuclear power plants

SKU: 2421447 Categories: ,

Description

N290.0-11 – General requirements for safety systems of nuclear power plants Preface This is the first edition of CSA N290.0, General requirements for safety systems of nuclear power plants. This Standard is one of a series of standards on reactor control systems, safety systems, and instrumentation for nuclear power plants. Scope 1.1 This Standard covers the design, qualification, installation, operation, maintenance, inspection, and documentation of the safety systems for a water-cooled nuclear power plant. 1.2 This Standard provides the general requirements for the safety systems. This Standard is a companion document of CSA N290.2 and N290.3, which outline specific requirements. 1.3 In CSA standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. ———————————————————————— N290.2-11 – Requirements for emergency core cooling systems of nuclear power plants Preface This is the first edition of CSA N290.2, Requirements for emergency core cooling systems of nuclear power plants . This Standard is one of a series of standards on reactor control systems, safety systems, and instrumentation for nuclear power plants. Scope 1.1 This Standard covers the design, qualification, installation, operation, maintenance, inspection, and documentation of the emergency core cooling (ECC) system for a water-cooled nuclear power plant. 1.2 The ECC system’s primary purpose is to transfer heat from the reactor core following a loss of reactor coolant that exceeds the makeup capability of process systems. This Standard also applies to all support systems required to ensure that the ECC system is able to maintain adequate heat transfer for as long as necessary to maintain the release of radioactive material within reference dose limits by limiting fuel failure. 1.3 This Standard was written as a companion document to CSA N290.0, which outlines general requirements for safety systems. 1.4 This Standard uses the term “ECC system” to refer to either a single system or multiple systems depending on the plant design. 1.5 In CSA standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

68

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

N290.0-11 - General requirements for safety systems of nuclear power plants Preface This is the first edition of CSA N290.0, General requirements for safety systems of nuclear power plants. This Standard is one of a series of standards on reactor control systems, safety systems, and instrumentation for nuclear power plants. Scope 1.1 This Standard covers the design, qualification, installation, operation, maintenance, inspection, and documentation of the safety systems for a water-cooled nuclear power plant. 1.2 This Standard provides the general requirements for the safety systems. This Standard is a companion document of CSA N290.2 and N290.3, which outline specific requirements. 1.3 In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. ------------------------------------------------------------------------ N290.2-11 - Requirements for emergency core cooling systems of nuclear power plants Preface This is the first edition of CSA N290.2, Requirements for emergency core cooling systems of nuclear power plants . This Standard is one of a series of standards on reactor control systems, safety systems, and instrumentation for nuclear power plants. Scope 1.1 This Standard covers the design, qualification, installation, operation, maintenance, inspection, and documentation of the emergency core cooling (ECC) system for a water-cooled nuclear power plant. 1.2 The ECC system's primary purpose is to transfer heat from the reactor core following a loss of reactor coolant that exceeds the makeup capability of process systems. This Standard also applies to all support systems required to ensure that the ECC system is able to maintain adequate heat transfer for as long as necessary to maintain the release of radioactive material within reference dose limits by limiting fuel failure. 1.3 This Standard was written as a companion document to CSA N290.0, which outlines general requirements for safety systems. 1.4 This Standard uses the term "ECC system" to refer to either a single system or multiple systems depending on the plant design. 1.5 In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: