Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CAN/CSA-E60730-2-7:18 (R2022)

CAN/CSA-E60730-2-7:18 (R2022) – Automatic electrical controls — Part 2-7: Particular requirements for timers and time switches (Adopted IEC 60730-2-7:2015, third edition , 2015-03, with Canadian deviations)

CDN $265.00

Automatic electrical controls — Part 2-7: Particular requirements for timers and time switches (Adopted IEC 60730-2-7:2015, third edition , 2015-03, with Canadian deviations)

SKU: 2425556 Categories: ,

Description

Preface This is the second edition of CAN/CSA-E60730-2-7, Automatic electrical controls — Part 2-7: Particular requirements for timers and time switches, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-7 (third edition, 2015-03). It supersedes the previous edition published in 1994 as CAN/CSA-E730-2-7 (adopted IEC 730-2-7:1990). At the time of publication, IEC 60730-2-7:2015 is available from IEC in English only. CSA Group will publish the French version when it becomes available from IEC.  For brevity, this Standard will be referred to as “CAN/CSA-E60730-2-7” throughout.  This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:13, Automatic electrical controls for household and similar use — Part 1: General requirements (adopted IEC 60730-1:2010, with Canadian deviations).  This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and normative references This clause of Part 1 is applicable except as follows:  1.1 Replacement:  In general, this part of IEC 60730 applies to timers and time switches that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications.  This Standard is also applicable to individual timers utilized as part of a control system or timers which are mechanically integral with multifunctional controls having non-electrical outputs. This Standard does not apply to time-delay switches (TDS) within the scope of IEC 60669-2-3.  NOTE 1 Throughout this standard, the word “timers” means timers and time switches, unless the type is specifically mentioned.  NOTE 2 Devices which only indicate time or passage of time are not included.  NOTE 3 This Standard does not apply to multi-functional controls having an integrated timing function which is not capable of being tested as a separate timing device.  1.1.1 Replacement:  This Standard applies to the inherent safety, to the operating characteristics where such are associated with equipment protection and to the testing of timers used in appliances and other apparatus, electrical and non-electrical, for household and similar purposes, but also extended to industrial purposes when no dedicated product standards exist, such as that for central heating, air conditioning, process heating, etc.  Timers for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.  This Standard is also applicable to timers for appliances within the scope of IEC 60335-1.  1.1.2 Replacement:  This Standard applies to manual controls when such are electrically and/or mechanically integral with timers.  1.4 Replacement:  This Standard applies also to timers incorporating electronic devices, requirements for which are contained in Annex H.  This Standard applies also to timers using NTC or PTC thermistors, requirements for which are contained in Part 1, Annex J.  1.5 Normative references This subclause of Part 1 applies except as follows:  Addition:  IEC 60669-1:1998, Switches for household and similar fixed-electrical installations – Part 1: General requirements  IEC 60669-1:1998/AMD1:1999  IEC 60669-1:1998/AMD2:2006  IEC 60695-11-10:2013, Fire hazard testing – Part 11-10: Test flames – 50 W horizontal and vertical flame test methods

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

45

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CAN/CSA-E60730-2-7, Automatic electrical controls — Part 2-7: Particular requirements for timers and time switches, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-7 (third edition, 2015-03). It supersedes the previous edition published in 1994 as CAN/CSA-E730-2-7 (adopted IEC 730-2-7:1990). At the time of publication, IEC 60730-2-7:2015 is available from IEC in English only. CSA Group will publish the French version when it becomes available from IEC.  For brevity, this Standard will be referred to as "CAN/CSA-E60730-2-7" throughout.  This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:13, Automatic electrical controls for household and similar use — Part 1: General requirements (adopted IEC 60730-1:2010, with Canadian deviations).  This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and normative references This clause of Part 1 is applicable except as follows:  1.1 Replacement:  In general, this part of IEC 60730 applies to timers and time switches that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications.  This Standard is also applicable to individual timers utilized as part of a control system or timers which are mechanically integral with multifunctional controls having non-electrical outputs. This Standard does not apply to time-delay switches (TDS) within the scope of IEC 60669-2-3.  NOTE 1 Throughout this standard, the word "timers" means timers and time switches, unless the type is specifically mentioned.  NOTE 2 Devices which only indicate time or passage of time are not included.  NOTE 3 This Standard does not apply to multi-functional controls having an integrated timing function which is not capable of being tested as a separate timing device.  1.1.1 Replacement:  This Standard applies to the inherent safety, to the operating characteristics where such are associated with equipment protection and to the testing of timers used in appliances and other apparatus, electrical and non-electrical, for household and similar purposes, but also extended to industrial purposes when no dedicated product standards exist, such as that for central heating, air conditioning, process heating, etc.  Timers for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.  This Standard is also applicable to timers for appliances within the scope of IEC 60335-1.  1.1.2 Replacement:  This Standard applies to manual controls when such are electrically and/or mechanically integral with timers.  1.4 Replacement:  This Standard applies also to timers incorporating electronic devices, requirements for which are contained in Annex H.  This Standard applies also to timers using NTC or PTC thermistors, requirements for which are contained in Part 1, Annex J.  1.5 Normative references This subclause of Part 1 applies except as follows:  Addition:  IEC 60669-1:1998, Switches for household and similar fixed-electrical installations – Part 1: General requirements  IEC 60669-1:1998/AMD1:1999  IEC 60669-1:1998/AMD2:2006  IEC 60695-11-10:2013, Fire hazard testing – Part 11-10: Test flames – 50 W horizontal and vertical flame test methods

Previous Editions

Can’t find what you are looking for?

Please contact us at: