
CSA 2.17:17 (R2026)
CSA 2.17:17 (R2026) – Gas-fired appliances for use at high altitudes
CDN $273.00
Gas-fired appliances for use at high altitudes
Description
Preface This is the fourth edition of CSA 2.17, Gas-fired appliances for use at high altitudes . It supersedes the previous edition published in 1991. This Standard was prepared by the Canadian Technical Committee on Gas Appliances and Related Accessories, under the jurisdiction of the Strategic Steering Committee on Standards for Fuel Burning Equipment, and had been formally approved by the Technical Committee, and the Interprovincial Gas Advisory Council. Scope 1.1 This Standard covers the construction and performance* (see Clause 3, Definitions) of gas-fired appliances with inputs up to and including 400 000 Btu/h (117.23 kW)† to determine their suitability for use at high altitude. The appliances include furnaces, boilers, room heaters, unit heaters, water heaters, and such other appliances where field conditions indicate the necessity of testing for high altitude use (see Clause 3, Definitions). The test rate means the appliance’s input at a datum of 600 ft (152 m) or 29.38 in Hg (99.2 kPa) pressure. * At the option of the manufacturer, tests specified in Clause 5, Performance, may be conducted at a high-altitude location. † This input limitation reflects what is currently required by inspection authorities in high-altitude areas (i.e., appliances under 400 000 Btu/h (117.23 kW) must meet the requirements of this Standard). Appliances with inputs in excess of 400 000 Btu/h (117.23 kW) may still be reviewed for compliance with this Standard. 1.2 This Standard applies to appliances specified in Clause 1.1 when for use over an altitude range of 2000 to 4500 ft (610 to 1370 m), or 0 to 4500 ft (0 to 1370 m). 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
19
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the fourth edition of CSA 2.17, Gas-fired appliances for use at high altitudes . It supersedes the previous edition published in 1991. This Standard was prepared by the Canadian Technical Committee on Gas Appliances and Related Accessories, under the jurisdiction of the Strategic Steering Committee on Standards for Fuel Burning Equipment, and had been formally approved by the Technical Committee, and the Interprovincial Gas Advisory Council. Scope 1.1 This Standard covers the construction and performance* (see Clause 3, Definitions) of gas-fired appliances with inputs up to and including 400 000 Btu/h (117.23 kW)† to determine their suitability for use at high altitude. The appliances include furnaces, boilers, room heaters, unit heaters, water heaters, and such other appliances where field conditions indicate the necessity of testing for high altitude use (see Clause 3, Definitions). The test rate means the appliance's input at a datum of 600 ft (152 m) or 29.38 in Hg (99.2 kPa) pressure. * At the option of the manufacturer, tests specified in Clause 5, Performance, may be conducted at a high-altitude location. † This input limitation reflects what is currently required by inspection authorities in high-altitude areas (i.e., appliances under 400 000 Btu/h (117.23 kW) must meet the requirements of this Standard). Appliances with inputs in excess of 400 000 Btu/h (117.23 kW) may still be reviewed for compliance with this Standard. 1.2 This Standard applies to appliances specified in Clause 1.1 when for use over an altitude range of 2000 to 4500 ft (610 to 1370 m), or 0 to 4500 ft (0 to 1370 m). 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA Z276.1:25 – Design requirements for marine structures (DRMS) associated with LNG facilities
CDN $472.00 Add to cart -

CSA Z245.16:26 – Induction bends
CDN $252.00 Add to cart -

CSA Z245.1:26 – Steel pipe
CDN $756.00 Add to cart -

CSA Z663:18 (R2023) – Land use planning in the vicinity of pipeline systems
CDN $315.00 Add to cart







