Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C88.1:18 (R2023)

CSA C88.1:18 (R2023) – Power transformer and reactor bushings

CDN $150.00

Power transformer and reactor bushings

SKU: 2426570 Categories: ,

Description

Preface This is the second edition of CAN/CSA-C88.1, Standard for power transformer and reactor bushings. It supersedes the previous edition published in 1996. In addition to general updating, this edition of the Standard includes the following key revisions: a) Reference publications and definitions have been expanded and updated. b) Voltage classifications were updated to reflect currently accepted values. c) The partial discharge measurement and dry 1 min low-frequency withstand test values were updated. This Standard was prepared by the Technical Committee on Power Transformers under the jurisdiction of the Strategic Steering Committee on Power Engineering and EMC, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to outdoor bushings that have lightning impulse insulation levels 110 – 1950 kV. They are for use as components of liquid-filled transformers and reactors on systems with a nominal voltage of 15–765 kV. 1.2 This Standard provides electrical characteristics and provides dimensions for standard ratings. 1.3 This Standard defines service conditions, ratings, general requirements, and test procedures. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

42

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CAN/CSA-C88.1, Standard for power transformer and reactor bushings. It supersedes the previous edition published in 1996. In addition to general updating, this edition of the Standard includes the following key revisions: a) Reference publications and definitions have been expanded and updated. b) Voltage classifications were updated to reflect currently accepted values. c) The partial discharge measurement and dry 1 min low-frequency withstand test values were updated. This Standard was prepared by the Technical Committee on Power Transformers under the jurisdiction of the Strategic Steering Committee on Power Engineering and EMC, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to outdoor bushings that have lightning impulse insulation levels 110 – 1950 kV. They are for use as components of liquid-filled transformers and reactors on systems with a nominal voltage of 15–765 kV. 1.2 This Standard provides electrical characteristics and provides dimensions for standard ratings. 1.3 This Standard defines service conditions, ratings, general requirements, and test procedures. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: