Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CAN/CSA-C838-13 (R2022)

CAN/CSA-C838-13 (R2022) – Energy efficiency test methods for three-phase variable frequency drive systems

CDN $487.00

Energy efficiency test methods for three-phase variable frequency drive systems

SKU: 2421778 Categories: ,

Description

Preface This is the first edition of CSA C838, Energy efficiency test methods for three-phase variable frequency drive systems. Variable frequency drives (VFDs) have the ability to vary the speed of the motor from 0% to its full range at an infinite range of torque. This Standard defines a testing methodology that provides performance information that can assist with the process of selecting a VFD adequate to the motor driven process. It is estimated that 30% of all industrial motor systems can potentially be improved by the use of VFDs to control speed and torque, resulting in large energy savings. CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, Efficiency Nova Scotia, Hydro-Québec, Manitoba Hydro, Natural Resources Canada (NRCan), the Ontario Ministry of Energy (OME), the Ontario Power Authority (OPA), and the Canadian Electricity Association (CEA). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by Subcommittee on Variable Frequency Drives, under the jurisdiction of the Technical Committee on Industrial Equipment and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard establishes the testing procedure for determining efficiencies under varying loads and speeds for three-phase output variable frequency drives (VFDs) with rated voltage up to 750 V. This test procedure is limited to a combination of one motor with one drive. This Standard applies to voltage source inverter (VSI) pulse-width modulated (PWM) drives for squirrel-cage induction motors and other three-phase VFD technologies commonly used with permanent magnet and reluctance motor-drive systems. This Standard does not cover VFDs with a rated voltage rating greater than 750 V. Ancillary equipment are not to be included unless they are contained within the confines of the input and output terminals of the VFD device, or a mandatory requirement for the operation of the VFD. Note: Small motors supplied with special purpose VFDs of the single- phase type are covered by CSA C747. 1.2 In CSA standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non- mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

44

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA C838, Energy efficiency test methods for three-phase variable frequency drive systems. Variable frequency drives (VFDs) have the ability to vary the speed of the motor from 0% to its full range at an infinite range of torque. This Standard defines a testing methodology that provides performance information that can assist with the process of selecting a VFD adequate to the motor driven process. It is estimated that 30% of all industrial motor systems can potentially be improved by the use of VFDs to control speed and torque, resulting in large energy savings. CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, Efficiency Nova Scotia, Hydro-Québec, Manitoba Hydro, Natural Resources Canada (NRCan), the Ontario Ministry of Energy (OME), the Ontario Power Authority (OPA), and the Canadian Electricity Association (CEA). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by Subcommittee on Variable Frequency Drives, under the jurisdiction of the Technical Committee on Industrial Equipment and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard establishes the testing procedure for determining efficiencies under varying loads and speeds for three-phase output variable frequency drives (VFDs) with rated voltage up to 750 V. This test procedure is limited to a combination of one motor with one drive. This Standard applies to voltage source inverter (VSI) pulse-width modulated (PWM) drives for squirrel-cage induction motors and other three-phase VFD technologies commonly used with permanent magnet and reluctance motor-drive systems. This Standard does not cover VFDs with a rated voltage rating greater than 750 V. Ancillary equipment are not to be included unless they are contained within the confines of the input and output terminals of the VFD device, or a mandatory requirement for the operation of the VFD. Note: Small motors supplied with special purpose VFDs of the single- phase type are covered by CSA C747. 1.2 In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non- mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: