Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C748:13 (R2023)

CSA C748:13 (R2023) – Performance of direct-expansion (DX) ground-source heat pumps

CDN $178.00

Performance of direct-expansion (DX) ground-source heat pumps

Description

Preface This is the second edition of CSA C748, Performance of direct-expansion (DX) ground-source heat pumps. It supersedes the previous edition published in 1994. The new edition of this Standard has been completely revised since the previous edition. This edition incorporates test methods used in CAN/CSA-C13256-1 and CAN/CSA-C13256-2, which have been adapted for the purposes of C748. The new edition incorporates changes to improve ease of use and include changes that reflect current industry practices. Changes introduced in this edition include the following: (a) A summary of the symbols used in this Standard; (b) Part 1 and Part 2 address DX-to-air and water separately, with both including requirements for rating, performance, testing, marking, installation, and publication of ratings; (c) The reference publications have been updated to reflect references to ISO standards; (d) New definitons have been added since the previous edition; and (e) New annexes related to test procedures, indoor/outdoor test methods, and instrumentation and measurements have also been added. CSA Group gratefully acknowledges the financial assistance provided by Natural Resources Canada, the Ontario Ministry of Energy, the Canadian Electricity Association, B.C. Hydro, and Manitoba Hydro in the development of this Standard. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Earth Energy Systems, under the jurisdiction of the Technical Committee on Heating, Ventilation, Air Conditioning and Refrigeration and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Part 1 of this Standard covers heating and cooling systems that are generally referred to as “direct-expansion-to-air heat pumps” (“DX-to-air heat pumps”). These systems generally include an indoor coil with air-moving means, a compressor, and a refrigerant-to- earth heat exchanger. A system may provide both heating and cooling, cooling-only, or heating-only functions. 1.2 Part 1 of this Standard establishes performance testing and rating criteria for factory-made, electrically-driven, mechanical-compression type, DX-to-air heat pumps for residential, commercial and industrial use. The requirements for testing and rating contained in Part 1 of this Standard are based on the use of matched assemblies. 1.3 Part 1 of this Standard does not apply to the testing and rating of individual assemblies for separate use, nor to the testing and rating of heat pumps covered in ISO 5151 or ISO 13253. Note: In this Standard, the terms “equipment” or “heat pumps” may be used to mean “DX-to-air heat pumps”. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

74

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA C748, Performance of direct-expansion (DX) ground-source heat pumps. It supersedes the previous edition published in 1994. The new edition of this Standard has been completely revised since the previous edition. This edition incorporates test methods used in CAN/CSA-C13256-1 and CAN/CSA-C13256-2, which have been adapted for the purposes of C748. The new edition incorporates changes to improve ease of use and include changes that reflect current industry practices. Changes introduced in this edition include the following: (a) A summary of the symbols used in this Standard; (b) Part 1 and Part 2 address DX-to-air and water separately, with both including requirements for rating, performance, testing, marking, installation, and publication of ratings; (c) The reference publications have been updated to reflect references to ISO standards; (d) New definitons have been added since the previous edition; and (e) New annexes related to test procedures, indoor/outdoor test methods, and instrumentation and measurements have also been added. CSA Group gratefully acknowledges the financial assistance provided by Natural Resources Canada, the Ontario Ministry of Energy, the Canadian Electricity Association, B.C. Hydro, and Manitoba Hydro in the development of this Standard. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Earth Energy Systems, under the jurisdiction of the Technical Committee on Heating, Ventilation, Air Conditioning and Refrigeration and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Part 1 of this Standard covers heating and cooling systems that are generally referred to as "direct-expansion-to-air heat pumps" ("DX-to-air heat pumps"). These systems generally include an indoor coil with air-moving means, a compressor, and a refrigerant-to- earth heat exchanger. A system may provide both heating and cooling, cooling-only, or heating-only functions. 1.2 Part 1 of this Standard establishes performance testing and rating criteria for factory-made, electrically-driven, mechanical-compression type, DX-to-air heat pumps for residential, commercial and industrial use. The requirements for testing and rating contained in Part 1 of this Standard are based on the use of matched assemblies. 1.3 Part 1 of this Standard does not apply to the testing and rating of individual assemblies for separate use, nor to the testing and rating of heat pumps covered in ISO 5151 or ISO 13253. Note: In this Standard, the terms "equipment" or "heat pumps" may be used to mean "DX-to-air heat pumps". 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.