
CSA C68.7:11 (R2025)
CSA C68.7:11 (R2025) – Underground secondary and service-entrance cable for electrical distribution utilities
CDN $236.00
Underground secondary and service-entrance cable for electrical distribution utilities
Description
Preface This is the first edition of CSA C68.7, Underground secondary and service-entrance cable for electrical distribution utilities. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for 600 V copper and aluminum conductor secondary and service-entrance cables intended primarily for operation by electrical utilities. These cables are intended for underground installation (a) by direct burial; or (b) in conduit systems. This Standard also applies to multiple-conductor cable assemblies. Notes: (1) The cables covered by this Standard are exposed to sunlight on terminal poles and during storage. (2) The operation of cables complying with this Standard by other than an electrical utility can be subject to additional requirements by an authority having jurisdiction. 1.2 This Standard applies to cables with (a) a maximum allowable conductor temperature of 75 °C or 90 °C; and (b) cold impact and cold bend ratings of -40 °C. 1.3 Cables rated at 75 °C are suitable for voltage regulation limited applications where ampacity considerations are not applicable. Cables rated at 90 °C are suitable for ampacity limited applications. 1.4 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
24
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of CSA C68.7, Underground secondary and service-entrance cable for electrical distribution utilities. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for 600 V copper and aluminum conductor secondary and service-entrance cables intended primarily for operation by electrical utilities. These cables are intended for underground installation (a) by direct burial; or (b) in conduit systems. This Standard also applies to multiple-conductor cable assemblies. Notes: (1) The cables covered by this Standard are exposed to sunlight on terminal poles and during storage. (2) The operation of cables complying with this Standard by other than an electrical utility can be subject to additional requirements by an authority having jurisdiction. 1.2 This Standard applies to cables with (a) a maximum allowable conductor temperature of 75 °C or 90 °C; and (b) cold impact and cold bend ratings of -40 °C. 1.3 Cables rated at 75 °C are suitable for voltage regulation limited applications where ampacity considerations are not applicable. Cables rated at 90 °C are suitable for ampacity limited applications. 1.4 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart







