
CAN/CSA-C61089-11 (R2025)
CAN/CSA-C61089-11 (R2025) – Round wire concentric lay overhead electrical stranded conductors (Adopted CEI/IEC 1089:1991, first edition, 1991-05, with Canadian deviations) | Conducteurs pour lignes aériennes à brins circulaires, câblés en couches concentriques (norme CEI/IEC 1089:1991 adoptée, première édition, 1991-05, avec exigences propres au Canada)
CDN $273.00
Round wire concentric lay overhead electrical stranded conductors (Adopted CEI/IEC 1089:1991, first edition, 1991-05, with Canadian deviations) | Conducteurs pour lignes aériennes à brins circulaires, câblés en couches concentriques (norme CEI/IEC 1089:1991 adoptée, première édition, 1991-05, avec exigences propres au Canada)
Description
CSA Preface This is the second edition of CAN/CSA-C61089, Round wire concentric lay overhead electrical stranded conductors , which is an adoption, with Canadian deviations, of the identically titled CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) Standard 1089 (first edition, 1991-05). It supersedes the previous edition published in 2003 as CAN/CSA-C61089. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope [Replace this clause with the following] 1.1 This Standard specifies the electrical and mechanical characteristics of round wire concentric lay overhead electrical stranded conductors made of combinations of any of the following metal wires: (a) aluminum wires: (i) hard-drawn aluminum in accordance with CAN/CSA-C60889, designated A1; (ii) aluminum alloy AA6101-T81 in accordance with CAN/CSA-C60104, designated A2; and (iii) aluminum alloy AA6101-T83 in accordance with CAN/CSA-C60104, designated A4; (b) zinc-coated steel wires in accordance with CAN/CSA-C60888: (i) regular strength steel, designated S1A or S1B, where A and B are zinc coating classes; (ii) high strength steel, designated S2A or S2B; and (iii) extra high strength steel, designated S3A; and (c) aluminum-clad steel wires in accordance with CAN/CSA-C61232 using Class 20, designated 20SA Type A, corresponding to a conductivity of 20.3% IACS. 1.2 The conductor designations covered by this Standard include but are not limited to (a) A1, A2, A4; (b) A1/S1A, A1/S1B, A1/S2A, A1/S2B, A1/S3A; (c) A2/S1A, A2/S1B, A2/S3A; (d) A1/20SA; and (e) A1/A2, A1/A4. ——————————————————————————————————————————– Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C61089, Conducteurs pour lignes aériennes à brins circulaires, câblés en couches concentriques. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme CEI (Commission Électrotechnique Internationale) 1089 (première édition, 1991-05) qui porte le même titre. Ce document remplace l’édition précédente publiée en 2003 qui portait la désignation CAN/CSA-C61089. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application [Remplacer cet article par le suivant] 1.1 Cette norme prescrit les caractéristiques électriques et mécaniques des conducteurs pour lignes aériennes à brins circulaires, câblés en couches concentriques fabriqués des combinaisons de fils métalliques suivantes : a) fils en aluminium : (i) aluminium écroui dur, conformément à la CAN/CSA-C60889, portant la désignation A1 ; (ii) alliage d’aluminium AA6101-T81, conformément à la CAN/CSA-C60104, portant la désignation A2 ; et (iii) alliage d’aluminium AA6101-T83 conformément à la CAN/CSA-C60104, portant la désignation A4 ; b) fils d’acier zingués, conformément à la CAN/CSA-C60888 : (i) acier de résistance normale, portant la désignation S1A ou S1B, pour lesquels A et B sont les classes de revêtement de zinc ; (ii) acier à haute résistance, portant la désignation S2A ou S2B ; et (iii) acier à très haute résistance, portant la désignation S3A ; et c) fils d’acier recouverts d’aluminium, conformément à la CAN/CSA-C61232 utilisant la classe 20, portant la désignation 20SA, type A, correspondant à une conductivité IACS de 20,3 %. 1.2 Les désignations des conducteurs inclus dans cette norme sont a) A1, A2, A4 ; b) A1/S1A, A1/S1B, A1/S2A, A1/S2B, A1/S3A ; c) A2/S1A, A2/S1B, A2/S3A ; d) A1/20SA ; et e) A1/A2, A1/A4.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
224
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CAN/CSA-C61089, Round wire concentric lay overhead electrical stranded conductors , which is an adoption, with Canadian deviations, of the identically titled CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) Standard 1089 (first edition, 1991-05). It supersedes the previous edition published in 2003 as CAN/CSA-C61089. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope [Replace this clause with the following] 1.1 This Standard specifies the electrical and mechanical characteristics of round wire concentric lay overhead electrical stranded conductors made of combinations of any of the following metal wires: (a) aluminum wires: (i) hard-drawn aluminum in accordance with CAN/CSA-C60889, designated A1; (ii) aluminum alloy AA6101-T81 in accordance with CAN/CSA-C60104, designated A2; and (iii) aluminum alloy AA6101-T83 in accordance with CAN/CSA-C60104, designated A4; (b) zinc-coated steel wires in accordance with CAN/CSA-C60888: (i) regular strength steel, designated S1A or S1B, where A and B are zinc coating classes; (ii) high strength steel, designated S2A or S2B; and (iii) extra high strength steel, designated S3A; and (c) aluminum-clad steel wires in accordance with CAN/CSA-C61232 using Class 20, designated 20SA Type A, corresponding to a conductivity of 20.3% IACS. 1.2 The conductor designations covered by this Standard include but are not limited to (a) A1, A2, A4; (b) A1/S1A, A1/S1B, A1/S2A, A1/S2B, A1/S3A; (c) A2/S1A, A2/S1B, A2/S3A; (d) A1/20SA; and (e) A1/A2, A1/A4. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C61089, Conducteurs pour lignes aériennes à brins circulaires, câblés en couches concentriques. Il s'agit de l'adoption, avec exigences propres au Canada, de la norme CEI (Commission Électrotechnique Internationale) 1089 (première édition, 1991-05) qui porte le même titre. Ce document remplace l'édition précédente publiée en 2003 qui portait la désignation CAN/CSA-C61089. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d'application [Remplacer cet article par le suivant] 1.1 Cette norme prescrit les caractéristiques électriques et mécaniques des conducteurs pour lignes aériennes à brins circulaires, câblés en couches concentriques fabriqués des combinaisons de fils métalliques suivantes : a) fils en aluminium : (i) aluminium écroui dur, conformément à la CAN/CSA-C60889, portant la désignation A1 ; (ii) alliage d'aluminium AA6101-T81, conformément à la CAN/CSA-C60104, portant la désignation A2 ; et (iii) alliage d'aluminium AA6101-T83 conformément à la CAN/CSA-C60104, portant la désignation A4 ; b) fils d'acier zingués, conformément à la CAN/CSA-C60888 : (i) acier de résistance normale, portant la désignation S1A ou S1B, pour lesquels A et B sont les classes de revêtement de zinc ; (ii) acier à haute résistance, portant la désignation S2A ou S2B ; et (iii) acier à très haute résistance, portant la désignation S3A ; et c) fils d'acier recouverts d'aluminium, conformément à la CAN/CSA-C61232 utilisant la classe 20, portant la désignation 20SA, type A, correspondant à une conductivité IACS de 20,3 %. 1.2 Les désignations des conducteurs inclus dans cette norme sont a) A1, A2, A4 ; b) A1/S1A, A1/S1B, A1/S2A, A1/S2B, A1/S3A ; c) A2/S1A, A2/S1B, A2/S3A ; d) A1/20SA ; et e) A1/A2, A1/A4.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.2-2017/CSA C293.2:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—Application guide for design, installation, testing, commissioning, and maintenance
CDN $158.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CSA SPE-1000:25 – Model Code for the field evaluation of electrical equipment
CDN $378.00 Add to cart -

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart







