
CSA C60079-30-2:17 (R2022)
CSA C60079-30-2:17 (R2022) – Explosive atmospheres — Part 30-2: Electrical resistance trace heating — Application guide for design, installation and maintenance (Adopted IEC/IEEE 60079-30-2:2015, first edition, 2015-09, with Canadian deviations)
CDN $535.00
Explosive atmospheres — Part 30-2: Electrical resistance trace heating — Application guide for design, installation and maintenance (Adopted IEC/IEEE 60079-30-2:2015, first edition, 2015-09, with Canadian deviations)
Description
CSA Preface This is the first edition of CAN/CSA-C60079-30-2, Explosive atmospheres — Part 30-2: Electrical resistance trace heating — Application guide for design, installation and maintenance , which is an adoption, with Canadian deviations, of the identically titled IEC/IEEE (International Electrotechnical Commission/Institute of Electrical and Electronics Engineers) Standard 60079-30-2 (first edition, 2015-09). At the time of publication, IEC/IEEE 60079-30-2:2015 is available from IEC and IEEE in English only. CSA Group will publish the French version when it becomes available from IEC and IEEE. For brevity, this Standard will be referred to as “CAN/CSA-C60079-30-2” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60079-30-1, Explosive atmospheres — Part 30-1: Electrical resistance trace heating — General and testing requirements, and CAN/CSA-C22.2 No. 60079-0, Explosive atmospheres — Part 0: Equipment — General requirements. This Standard was reviewed for Canadian adoption by the CSA Integrated Committee on Trace Heating, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 60079 provides guidance for the application of electrical resistance trace heating systems in areas where explosive atmospheres may be present, with the exclusion of those classified as requiring EPL Ga/Da (traditional relationship to Zone 0 and Zone 20 respectively). This standard also provides guidance for explosive atmospheres incorporating the Division method of area classification that may be applied by some users of this standard. NOTE Information on the Division method is given in NFPA 70 and CSA C22.1. It provides recommendations for the design, installation, maintenance and repair of trace heating systems including associated control and monitoring equipment. It does not cover devices that operate by induction heating, skin effect heating or direct pipeline heating, nor those intended for stress relieving.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
85
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the first edition of CAN/CSA-C60079-30-2, Explosive atmospheres — Part 30-2: Electrical resistance trace heating — Application guide for design, installation and maintenance , which is an adoption, with Canadian deviations, of the identically titled IEC/IEEE (International Electrotechnical Commission/Institute of Electrical and Electronics Engineers) Standard 60079-30-2 (first edition, 2015-09). At the time of publication, IEC/IEEE 60079-30-2:2015 is available from IEC and IEEE in English only. CSA Group will publish the French version when it becomes available from IEC and IEEE. For brevity, this Standard will be referred to as "CAN/CSA-C60079-30-2" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60079-30-1, Explosive atmospheres — Part 30-1: Electrical resistance trace heating — General and testing requirements, and CAN/CSA-C22.2 No. 60079-0, Explosive atmospheres — Part 0: Equipment — General requirements. This Standard was reviewed for Canadian adoption by the CSA Integrated Committee on Trace Heating, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 60079 provides guidance for the application of electrical resistance trace heating systems in areas where explosive atmospheres may be present, with the exclusion of those classified as requiring EPL Ga/Da (traditional relationship to Zone 0 and Zone 20 respectively). This standard also provides guidance for explosive atmospheres incorporating the Division method of area classification that may be applied by some users of this standard. NOTE Information on the Division method is given in NFPA 70 and CSA C22.1. It provides recommendations for the design, installation, maintenance and repair of trace heating systems including associated control and monitoring equipment. It does not cover devices that operate by induction heating, skin effect heating or direct pipeline heating, nor those intended for stress relieving.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E60825-1:15 (R2025) – Safety of laser products — Part 1: Equipment classification and requirements (Adopted IEC 60825-1:2014, third edition, 2014-05, with Canadian deviations) | Sécurité des appareils à laser — Partie 1 : Classification des matériels et exigences (norme IEC 60825-1:2014 adoptée, troisième édition, 2014-05, avec exigences propres au Canada)
CDN $488.00 Add to cart -

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart -

CSA C22.3 NO. 5.1:93 (R2022) – Recommended practices for electrical protection – Electric contact between overhead supply and communication lines
CDN $149.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart







