Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

B51-14 (R2019) – Boiler, pressure vessel, and pressure piping code

$

362

BUY NOW

CSA C504:20 (R2025)

CSA C504:20 (R2025) – Measuring and monitoring industrial and commercial pumping system energy performance

CDN $315.00

Measuring and monitoring industrial and commercial pumping system energy performance

SKU: 2428131 Categories: ,

Description

Preface This is the first edition of CSA C504, Measuring and monitoring industrial and commercial pumping system energy performance . CSA Group acknowledges that the development of this Standard was made possible in part by the financial support of BC Hydro, the Canadian Electricity Association (CEA), Hydro Québec, Independent Electricity System Operator, Manitoba Hydro, and Natural Resources Canada (NRCan). This Standard was prepared by the Subcommittee on Benchmark Energy Factor For Pump Systems, under the jurisdiction of the Technical Committee on Energy Efficiency of Industrial Equipment and Systems and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard is intended to be used with an industrial or commercial clean-water pumping system with the following characteristics: a) any application of electrically driven single- and multi-stage rotodynamic pumps; b) pumping system with a flow range between 20 m3/h to 36 000 m3/h; and c) all liquids with viscosity up to 25 cSt, provided that ANSI/HI 9.6.7 is used to correct the performance to 1 cSt. 1.2 Exclusions This Standard is not intended to be used with the following pumping systems: a) application of positive displacement pumps, defined as a category of pumps where a set volume of liquid is trapped in a chamber and conveyed from the suction side of the pump to the discharge side of the pump through displacement of liquid by a solid component such as a piston, plunger, gear tooth, vane, screw, diaphragm, etc.; and b) pumping system applications handling shear-sensitive liquids. 1.3 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

56

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA C504, Measuring and monitoring industrial and commercial pumping system energy performance . CSA Group acknowledges that the development of this Standard was made possible in part by the financial support of BC Hydro, the Canadian Electricity Association (CEA), Hydro Québec, Independent Electricity System Operator, Manitoba Hydro, and Natural Resources Canada (NRCan). This Standard was prepared by the Subcommittee on Benchmark Energy Factor For Pump Systems, under the jurisdiction of the Technical Committee on Energy Efficiency of Industrial Equipment and Systems and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard is intended to be used with an industrial or commercial clean-water pumping system with the following characteristics: a) any application of electrically driven single- and multi-stage rotodynamic pumps; b) pumping system with a flow range between 20 m3/h to 36 000 m3/h; and c) all liquids with viscosity up to 25 cSt, provided that ANSI/HI 9.6.7 is used to correct the performance to 1 cSt. 1.2 Exclusions This Standard is not intended to be used with the following pumping systems: a) application of positive displacement pumps, defined as a category of pumps where a set volume of liquid is trapped in a chamber and conveyed from the suction side of the pump to the discharge side of the pump through displacement of liquid by a solid component such as a piston, plunger, gear tooth, vane, screw, diaphragm, etc.; and b) pumping system applications handling shear-sensitive liquids. 1.3 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: