
CSA C50069:24
CSA C50069:24 – High-voltage switchgear and controlgear — Gas-filled welded composite enclosures of cast and wrought aluminium alloys (Adopted CENELEC EN 50069:2018, 2018-11, with Canadian deviations)
CDN $425.00
High-voltage switchgear and controlgear — Gas-filled welded composite enclosures of cast and wrought aluminium alloys (Adopted CENELEC EN 50069:2018, 2018-11, with Canadian deviations)
Description
CSA Preface This is the second edition of CSA C50069, High-voltage switchgear and controlgear — Gas-filled welded composite enclosures of cast and wrought aluminium alloys , which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50069 (2018-11). It supersedes the previous edition published in 1999 as CSA C50069 (adopted EN 50069:1991). For brevity, this Standard will be referred to as “CSA C50069” throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, FortisBC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This document applies to welded composite enclosures of cast and wrought aluminium alloy pressurized with dry air, inert gases (e.g. sulphur hexafluoride or nitrogen or a mixture of such gases), used in indoor and outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1 kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages: — above 1 kV and up to and including 52 kV concerning gas-filled compartments with design pressure higher than 300 kPa relative pressure (gauge); — above 52 kV concerning all gas-filled compartments. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: — circuit-breakers; — switch-disconnectors; — disconnectors; — earthing switches; — current transformers; — voltage transformers; — surge arrestors; — busbars and connections; — etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
30
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CSA C50069, High-voltage switchgear and controlgear — Gas-filled welded composite enclosures of cast and wrought aluminium alloys , which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50069 (2018-11). It supersedes the previous edition published in 1999 as CSA C50069 (adopted EN 50069:1991). For brevity, this Standard will be referred to as "CSA C50069" throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, FortisBC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This document applies to welded composite enclosures of cast and wrought aluminium alloy pressurized with dry air, inert gases (e.g. sulphur hexafluoride or nitrogen or a mixture of such gases), used in indoor and outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1 kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages: — above 1 kV and up to and including 52 kV concerning gas-filled compartments with design pressure higher than 300 kPa relative pressure (gauge); — above 52 kV concerning all gas-filled compartments. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: — circuit-breakers; — switch-disconnectors; — disconnectors; — earthing switches; — current transformers; — voltage transformers; — surge arrestors; — busbars and connections; — etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E60730-2-9:18 (R2023) – Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted IEC 60730-2-9:2018, edition 4:2015 consolidated with amendment 1:2018, with Canadian deviations)
CDN $944.00 Add to cart -

CSA E62660-1:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 1: Performance testing (Adopted IEC 62660-1:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 1 : Essais de performance (norme IEC 62660-1:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $436.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA G164:26 – Galvanizing of irregularly shaped articles
CDN $142.00 Add to cart







