
CSA C50089:99 (R2026)
CSA C50089:99 (R2026) – Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear (Adopted CENELEC 50089:1992, including amendment A1:1994, with Canadian deviations)
CDN $104.00
Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear (Adopted CENELEC 50089:1992, including amendment A1:1994, with Canadian deviations)
Description
CSA Preface This is the first edition of CSA Standard CAN/CSA-C50089, Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50 089 : 1 992 (1 992-05) including Amendment Al :1 994. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 2.1 Type of Equipment This standard applies to cast resin partitions pressurized with inert gases, eg, sulphur hexafluoride, carbon tetrafluoride, or a mixture of such gases, such as sulphur hexafluoride and nitrogen used in indoor and outdoor installations of high-voltage switchgear and controlgear, where the gas is used principally for its dielectric and/or arc-quenching properties, with rated voltages (a) 1 kV and up to and including 52 kV and with gas-filled compartments with design pressure greater than 3 bar (gauge); and (b) 72.5 kV and above. The partitions comprise pressurized barriers in electrical equipment not necessarily limited to the following examples: – Circuit breakers – Switch disconnectors – Disconnectors – Earthing switches – Current transformers – Voltage transformers -Surge arresters – Busbars and connections – Cable and connections. This standard does not apply to high-voltage bushings (see HD 358 S3 (IEC 517)). 2.2 Quality assurance It is the intention of this standard that the switchgear manufacturer shall be responsible for achieving and maintaining a consistent and adequate quality of product. Sufficient examinations shall be made by the partition manufacturer to ensure that the materials, production and testing comply in all respects with the requirements of this standard. Inspections by the users’ inspectors shall not absolve the switchgear manufacturer from his responsibility to exercise such quality assurance procedures as to ensure that the requirements and intent of this standard are satisfied. NOTE. Reference should he made to the EN 2900() series of standards for quality assurance systems.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the first edition of CSA Standard CAN/CSA-C50089, Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50 089 : 1 992 (1 992-05) including Amendment Al :1 994. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 2.1 Type of Equipment This standard applies to cast resin partitions pressurized with inert gases, eg, sulphur hexafluoride, carbon tetrafluoride, or a mixture of such gases, such as sulphur hexafluoride and nitrogen used in indoor and outdoor installations of high-voltage switchgear and controlgear, where the gas is used principally for its dielectric and/or arc-quenching properties, with rated voltages (a) 1 kV and up to and including 52 kV and with gas-filled compartments with design pressure greater than 3 bar (gauge); and (b) 72.5 kV and above. The partitions comprise pressurized barriers in electrical equipment not necessarily limited to the following examples: - Circuit breakers - Switch disconnectors - Disconnectors - Earthing switches - Current transformers - Voltage transformers -Surge arresters - Busbars and connections - Cable and connections. This standard does not apply to high-voltage bushings (see HD 358 S3 (IEC 517)). 2.2 Quality assurance It is the intention of this standard that the switchgear manufacturer shall be responsible for achieving and maintaining a consistent and adequate quality of product. Sufficient examinations shall be made by the partition manufacturer to ensure that the materials, production and testing comply in all respects with the requirements of this standard. Inspections by the users' inspectors shall not absolve the switchgear manufacturer from his responsibility to exercise such quality assurance procedures as to ensure that the requirements and intent of this standard are satisfied. NOTE. Reference should he made to the EN 2900() series of standards for quality assurance systems.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart -

CSA SPE-3000:19 – Model code for the field evaluation of medical electrical equipment (MEE) and medical electrical systems (MES)
CDN $334.00 Add to cart -

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart -

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart







