
CSA C50064:24
CSA C50064:24 – High-voltage switchgear and controlgear — Gas-filled wrought aluminium and aluminium alloy enclosures (Adopted CENELEC EN 50064:2018, 2018-11, with Canadian deviations)
CDN $551.00
High-voltage switchgear and controlgear — Gas-filled wrought aluminium and aluminium alloy enclosures (Adopted CENELEC EN 50064:2018, 2018-11, with Canadian deviations)
Description
CSA Preface This is the second edition of CSA C50064, High-voltage switchgear and controlgear — Gas-filled wrought aluminium and aluminium alloy enclosures, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50064 (2018-11). It supersedes the previous edition published in 1999 as CSA C50064 (adopted EN 50064:1989). For brevity, this Standard will be referred to as “CSA C50064” throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, Fortis BC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This document applies to wrought aluminium and aluminium alloy enclosures and their welding. These enclosures are pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor and outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1 kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages. — above 1 kV and up to and including 52 kV concerning gas-filled compartments with design pressure higher than 300 kPa relative pressure (gauge); — above 52 kV concerning all gas-filled compartments. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: — circuit-breakers; — switch-disconnectors; — disconnectors; — earthing switches; — current transformers; — voltage transformers; — surge arrestors; — busbars and connections; — etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
44
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CSA C50064, High-voltage switchgear and controlgear — Gas-filled wrought aluminium and aluminium alloy enclosures, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50064 (2018-11). It supersedes the previous edition published in 1999 as CSA C50064 (adopted EN 50064:1989). For brevity, this Standard will be referred to as "CSA C50064" throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, Fortis BC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This document applies to wrought aluminium and aluminium alloy enclosures and their welding. These enclosures are pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor and outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1 kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages. — above 1 kV and up to and including 52 kV concerning gas-filled compartments with design pressure higher than 300 kPa relative pressure (gauge); — above 52 kV concerning all gas-filled compartments. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: — circuit-breakers; — switch-disconnectors; — disconnectors; — earthing switches; — current transformers; — voltage transformers; — surge arrestors; — busbars and connections; — etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

CSA E61347-1:24 – Lamp controlgear – Part 1: General and safety requirements (Adopted IEC 61347-1:2015, edition 3:2015 consolidated with amendment 1:2017, with Canadian deviations) | Appareillages de lampes – Partie 1 : Exigences générales et exigences de sécurité (norme IEC 61347-1:2015 adoptée, édition 3:2015 consolidée par l’amendement 1:2017), avec exigences propres au Canada)
CDN $907.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart







