Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C500.1:24

CSA C500.1:24 – Benchmark energy factor (BEF) assessment of industrial refrigeration systems

CDN $252.00

Benchmark energy factor (BEF) assessment of industrial refrigeration systems

SKU: 2431288 Categories: ,

Description

Preface This is the first edition of CSA C500.1, Benchmark energy factor (BEF) assessment of industrial refrigeration systems . It supersedes CSA C500, which was published in 2018 under the title Monitoring and energy performance measurement of industrial refrigeration systems (IRS) using benchmark energy factor (BEF) concepts. CSA C500 has been separated into two Standards: CSA C500.1, which incorporates the requirements for refrigerated spaces and processes; and CSA C500.2, which incorporates the refrigeration requirements at a facility level. The following are the major ways in which this Standard differs from the relevant corresponding parts of CSA C500: a) The Standard has been aligned with more recent BEF standards in terms of document structure, language, terminology, and definitions. b) Essential load and energy determination have been simplified and user inputs have been reduced to make the Standard more user-friendly. c) Essential performance factors used for essential load and energy have been confirmed or updated. d) Required corrections and recommendations identified from the validation study have been incorporated. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, Efficiency Manitoba, Electricity Canada, FortisBC, Hydro-Québec, Independent Electricity System Operator (IESO), and the Québec Ministère de l’Environnement, de la Lutte contre les changements climatiques, de la Faune et des Parcs. This Standard was prepared by the Subcommittee on Industrial Refrigeration Systems, under the jurisdiction of the Technical Committee on Energy Efficiency of Industrial Equipment and Systems and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard provides requirements for benchmark energy factor (BEF) assessment intended for refrigeration systems with the following characteristics: a) refrigerated storage and refrigerated processes for food and beverage products; b) vapour-compression cycle that provides cooling by convection or conduction; c) refrigerated zone volume equal to or greater than 283 m 3 (10 000 ft 3 ); and d) process cooling capacity equal to or greater than 70 kW R (20 TR). 1.2 Exclusions This Standard is not intended for the following systems: a) stand-alone packaged walk-in coolers and freezer units; b) mobile refrigeration units; c) cryogenic freezing processes; and d) grocery and retail facilities. 1.3 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

58

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA C500.1, Benchmark energy factor (BEF) assessment of industrial refrigeration systems . It supersedes CSA C500, which was published in 2018 under the title Monitoring and energy performance measurement of industrial refrigeration systems (IRS) using benchmark energy factor (BEF) concepts. CSA C500 has been separated into two Standards: CSA C500.1, which incorporates the requirements for refrigerated spaces and processes; and CSA C500.2, which incorporates the refrigeration requirements at a facility level. The following are the major ways in which this Standard differs from the relevant corresponding parts of CSA C500: a) The Standard has been aligned with more recent BEF standards in terms of document structure, language, terminology, and definitions. b) Essential load and energy determination have been simplified and user inputs have been reduced to make the Standard more user-friendly. c) Essential performance factors used for essential load and energy have been confirmed or updated. d) Required corrections and recommendations identified from the validation study have been incorporated. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, Efficiency Manitoba, Electricity Canada, FortisBC, Hydro-Québec, Independent Electricity System Operator (IESO), and the Québec Ministère de l’Environnement, de la Lutte contre les changements climatiques, de la Faune et des Parcs. This Standard was prepared by the Subcommittee on Industrial Refrigeration Systems, under the jurisdiction of the Technical Committee on Energy Efficiency of Industrial Equipment and Systems and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard provides requirements for benchmark energy factor (BEF) assessment intended for refrigeration systems with the following characteristics: a) refrigerated storage and refrigerated processes for food and beverage products; b) vapour-compression cycle that provides cooling by convection or conduction; c) refrigerated zone volume equal to or greater than 283 m 3 (10 000 ft 3 ); and d) process cooling capacity equal to or greater than 70 kW R (20 TR). 1.2 Exclusions This Standard is not intended for the following systems: a) stand-alone packaged walk-in coolers and freezer units; b) mobile refrigeration units; c) cryogenic freezing processes; and d) grocery and retail facilities. 1.3 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: