
CSA C411.4:16 (R2026)
CSA C411.4:16 (R2026) – Composite suspension insulators for overhead lines > 75 kV
CDN $295.00
Composite suspension insulators for overhead lines > 75 kV
Description
Preface This is the third edition of CSA C411.4, Composite suspension insulators for overhead lines > 75 kV. It supersedes the previous editions, published in 2010 and 1998. Significant changes in this edition include – the addition of a flammability test; – revisions to the critical impulse flashover test; – revisions to the wet power frequency voltage flashover test; and – an updated mechanical load-time test. This Standard has also been updated to reflect current industry practice and to make reference to international standards where applicable. This Standard is one of the CSA C411 series of Standards covering insulators. The other Standards in the series are – CSA C411.1, AC suspension insulators; – CSA C411.5, Dead-end/suspension composite insulators for overhead lines ≤ 75 kV; – CSA C411.6, Line post composite insulators for overhead distribution lines; and – CSA C411.7, Composite insulators for guy wires. This Standard is based on the requirements of IEC 61109:2008, Insulators for overhead lines — Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V — Definitions, test methods and acceptance criteria. In addition, this Standard includes physical, electrical, and mechanical characteristics, and end fitting types and dimensions according to the insulator types in CSA C411.1, in order to provide a complete insulator specification. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to suspension and dead-end composite insulators used on ac overhead transmission lines with a nominal voltage greater than 75 kV and a frequency not greater than 100 Hz. 1.2 This Standard specifies a) insulator characteristics (mechanical, electrical, and dimensional) and prescribe the conditions under which these characteristics are to be verified; b) test methods; and c) acceptance criteria. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
59
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the third edition of CSA C411.4, Composite suspension insulators for overhead lines > 75 kV. It supersedes the previous editions, published in 2010 and 1998. Significant changes in this edition include - the addition of a flammability test; - revisions to the critical impulse flashover test; - revisions to the wet power frequency voltage flashover test; and - an updated mechanical load-time test. This Standard has also been updated to reflect current industry practice and to make reference to international standards where applicable. This Standard is one of the CSA C411 series of Standards covering insulators. The other Standards in the series are - CSA C411.1, AC suspension insulators; - CSA C411.5, Dead-end/suspension composite insulators for overhead lines ≤ 75 kV; - CSA C411.6, Line post composite insulators for overhead distribution lines; and - CSA C411.7, Composite insulators for guy wires. This Standard is based on the requirements of IEC 61109:2008, Insulators for overhead lines — Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V — Definitions, test methods and acceptance criteria. In addition, this Standard includes physical, electrical, and mechanical characteristics, and end fitting types and dimensions according to the insulator types in CSA C411.1, in order to provide a complete insulator specification. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to suspension and dead-end composite insulators used on ac overhead transmission lines with a nominal voltage greater than 75 kV and a frequency not greater than 100 Hz. 1.2 This Standard specifies a) insulator characteristics (mechanical, electrical, and dimensional) and prescribe the conditions under which these characteristics are to be verified; b) test methods; and c) acceptance criteria. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart







