CSA C22.3 NO. 4:74 (R2025)
CSA C22.3 NO. 4:74 (R2025) – Control of electrochemical corrosion of underground metallic structures
CDN $134.00
Control of electrochemical corrosion of underground metallic structures
Description
Preface This is the third edition of C22.3 No. 4, it supersedes previous editions published in 1936 and 1958. In the first edition, major emphasis was placed upon the corrosive effects of stray currents originating in direct-current electric railway systems. In fact, the title of the first edition was “Principles and Practices for Protecting Underground Structures from the Effects of Stray Currents Originating in Direct-Current Electric Railway Systems”. In preparing the second edition of C22.3 No. 4, the Committee recognized certain major changes that were occurring throughout the country. Many transportation systems had discontinued operation of electrically operated railways employing grounded rails, or were in the process of eliminating this type of system. For this reason, the stray current situation was undergoing a radical change, and often this change resulted in more severe corrosion problems than existed during the operation of the electric railway. For example, many street railways have in the past cooperated extensively with the owners of other subsurface structures by, designing their systems to limit stray currents and by permitting the installation of drainage bonds between the two systems at strategic locations. The net result of this cooperation has been a large measure of cathodic protection to the other system. With the elimination of the street railway, however, this protection has been withdrawn, and corrosion due to other causes has been permitted to take place. It should be recognized that electrically operated railways employing grounded rail returns are not the only source of stray currents. Other types of systems utilizing grounded direct-current circuits often act as sources of stray currents in the earth. One such source that is becoming of major importance is the pipeline equipped with cathodic protection. While the electric railway is becoming of decreasing importance as a source of stray currents, considerable experience in the mitigation of corrosion due to stray currents originating in such railways has accumulated over the years. For this reason some of the Rules contained in this Code apply specifically to railways. It should be realized, however, that these Rules apply in general to all systems which originate stray earth currents, and that railways are mentioned specifically merely for convenience. The Committee charged with the preparation of the second edition foresaw the gradual abolition of electric railways and attempted to emphasize cathodic protection systems as a new and important source of stray dc current. In the interim between the publication of the second edition and the preparation of the third edition it is now apparent that electric traction systems may see increasing use in urban and inter-urban service. With the advent of high voltage direct current transmission for the long distance transportation of power and the almost universal use of cathodic protection on oil and gas piping systems the up-dating of this Standard is most timely. This Standard was prepared by the Task Group on Electrochemical Corrosion of Underground Metallic Structures under the jurisdiction of the Subcommittee on Ground Current Coordination and the Committee on Canadian Electrical Code, Part III and was formally approved by these Committees. Scope 1.1 The provisions of this Standard, forming a part of the Canadian Electrical Code, Part III, embody the applicable principles and general practices where underground metallic structures are subject to the risk of electro-chemical corrosion. 1.2 This Standard is issued for the guidance of all parties owning, controlling, or operating grounded electric systems and subsurface structures such as metallic pipes, metallic cable sheaths, or other structures with underground metallic components.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
28
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the third edition of C22.3 No. 4, it supersedes previous editions published in 1936 and 1958. In the first edition, major emphasis was placed upon the corrosive effects of stray currents originating in direct-current electric railway systems. In fact, the title of the first edition was "Principles and Practices for Protecting Underground Structures from the Effects of Stray Currents Originating in Direct-Current Electric Railway Systems". In preparing the second edition of C22.3 No. 4, the Committee recognized certain major changes that were occurring throughout the country. Many transportation systems had discontinued operation of electrically operated railways employing grounded rails, or were in the process of eliminating this type of system. For this reason, the stray current situation was undergoing a radical change, and often this change resulted in more severe corrosion problems than existed during the operation of the electric railway. For example, many street railways have in the past cooperated extensively with the owners of other subsurface structures by, designing their systems to limit stray currents and by permitting the installation of drainage bonds between the two systems at strategic locations. The net result of this cooperation has been a large measure of cathodic protection to the other system. With the elimination of the street railway, however, this protection has been withdrawn, and corrosion due to other causes has been permitted to take place. It should be recognized that electrically operated railways employing grounded rail returns are not the only source of stray currents. Other types of systems utilizing grounded direct-current circuits often act as sources of stray currents in the earth. One such source that is becoming of major importance is the pipeline equipped with cathodic protection. While the electric railway is becoming of decreasing importance as a source of stray currents, considerable experience in the mitigation of corrosion due to stray currents originating in such railways has accumulated over the years. For this reason some of the Rules contained in this Code apply specifically to railways. It should be realized, however, that these Rules apply in general to all systems which originate stray earth currents, and that railways are mentioned specifically merely for convenience. The Committee charged with the preparation of the second edition foresaw the gradual abolition of electric railways and attempted to emphasize cathodic protection systems as a new and important source of stray dc current. In the interim between the publication of the second edition and the preparation of the third edition it is now apparent that electric traction systems may see increasing use in urban and inter-urban service. With the advent of high voltage direct current transmission for the long distance transportation of power and the almost universal use of cathodic protection on oil and gas piping systems the up-dating of this Standard is most timely. This Standard was prepared by the Task Group on Electrochemical Corrosion of Underground Metallic Structures under the jurisdiction of the Subcommittee on Ground Current Coordination and the Committee on Canadian Electrical Code, Part III and was formally approved by these Committees. Scope 1.1 The provisions of this Standard, forming a part of the Canadian Electrical Code, Part III, embody the applicable principles and general practices where underground metallic structures are subject to the risk of electro-chemical corrosion. 1.2 This Standard is issued for the guidance of all parties owning, controlling, or operating grounded electric systems and subsurface structures such as metallic pipes, metallic cable sheaths, or other structures with underground metallic components.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA TS-117:23 – National technical specification for terminology for the decentralized energy industry in Canada
CDN $79.00 Add to cart -

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CSA C22.3 NO. 5.1:93 (R2022) – Recommended practices for electrical protection – Electric contact between overhead supply and communication lines
CDN $149.00 Add to cart