Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 96:23

CSA C22.2 NO. 96:23 – Portable power cables

CDN $510.00

Portable power cables

SKU: 2431093 Categories: ,

Description

Preface This is the twelfth edition of CSA C22.2 No. 96, Portable power cables, one of a series of Standards issued by CSA Group under the Canadian Electrical Code, Part II. It supersedes the previous editions, published in 2017, 2013, 2009, 2003, 1998, 1992, 1989, 1974, 1964, 1958, and 1951. The following are major changes to this edition: a) the addition of a new Clause (Clause 16) to cover special construction cable types SHD-SP, SHD-GC-SP, and SHD-BGC-SP, rated 2 kV up to 35 kV; b) clarifications of the weather resistance requirements; and c) updates to the cross-section drawings in Annex B. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Portable, Mine Power Feeder and Wind Turbine Cables, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies construction and testing requirements for portable power cables normally used in applications where the cables are subject to frequent flexing and where installation is in accordance with CSA M421 and/or the Canadian Electrical Code, Part I, where applicable. 1.2 The cable constructions specified in Clauses 5 to 9 and Clauses 12 to 16 of this Standard are suitable for use at a maximum conductor temperature of 90 °C under normal operating conditions in wet or dry locations, outdoors or in underground mines, and in rugged environments. The special cable constructions described in Clauses 10 and 11 are suitable for use at a maximum conductor temperature of 105 °C. 1.3 This Standard does not specify all types, sizes, and voltage ratings of portable power cables that can be required for particular applications. 1.4 This Standard specifies the following categories of cables: Clause 5 / Category – Thermoset and PUR multiconductor round cables for mining and general applications rated 5 kV – 35 kV – Types: SHD, SHD-BGC (balanced ground check), SHD-GC Clause 6 / Category – Thermoset and PUR multiconductor round cables for mining and general applications rated 2 kV – Types: W, G, G-BGC (balanced ground check), G-GC, SHC-GC, SHD, SHD-BGC (balanced ground check), SHD-GC, SHD-R Clause 7 / Category – Thermoset single-conductor cables for mining and general applications rated 2 kV – 35 kV – Types: W, SH Clause 8 / Category – Thermoset two- and three-conductor flat cables for mining and general applications rated 2 kV — Suitable for underground applications only – Types: G, G-GC, W Clause 9 / Category – Thermoset three-conductor round cables with a central bonding conductor for underground coal mining applications rated 2 kV – 5 kV – Types: SHD-PCG Clause 10 / Category – Arc-welding cable Clause 11 / Category – Single-conductor portable power cable rated 600 V – Types: PPC, PPC/TPE Clause 12 / Category – Single and multiconductor portable power cables for general applications rated 600 V – 2 kV – Types: PPC, PPC/TPE Clause 13 / Category – Flexible multiconductor cable for use with cranes and hoists rated 600 V (festoon cable) Clause 14 / Category – Variable frequency drive cable, multiconductor, round, for mining and general applications rated 2 kV – 15 kV – Types: VFD, VFD-GC, VFD-BGC (balanced ground check) Clause 15 / Category – DLO (diesel locomotive) cable, single conductor, used for portable and general permanent applications rated 2 kV Clause 16 / Category – Thermoset and PUR multiconductor round special construction cables for mining and general applications rated 2 kV – 35 kV – Types: SHD-SP, SHD-BGC-SP (balanced ground check), SHD-GC-SP 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 The values given in SI units are the units of record for the purposes of this Standard.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

149

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the twelfth edition of CSA C22.2 No. 96, Portable power cables, one of a series of Standards issued by CSA Group under the Canadian Electrical Code, Part II. It supersedes the previous editions, published in 2017, 2013, 2009, 2003, 1998, 1992, 1989, 1974, 1964, 1958, and 1951. The following are major changes to this edition: a) the addition of a new Clause (Clause 16) to cover special construction cable types SHD-SP, SHD-GC-SP, and SHD-BGC-SP, rated 2 kV up to 35 kV; b) clarifications of the weather resistance requirements; and c) updates to the cross-section drawings in Annex B. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Portable, Mine Power Feeder and Wind Turbine Cables, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies construction and testing requirements for portable power cables normally used in applications where the cables are subject to frequent flexing and where installation is in accordance with CSA M421 and/or the Canadian Electrical Code, Part I, where applicable. 1.2 The cable constructions specified in Clauses 5 to 9 and Clauses 12 to 16 of this Standard are suitable for use at a maximum conductor temperature of 90 °C under normal operating conditions in wet or dry locations, outdoors or in underground mines, and in rugged environments. The special cable constructions described in Clauses 10 and 11 are suitable for use at a maximum conductor temperature of 105 °C. 1.3 This Standard does not specify all types, sizes, and voltage ratings of portable power cables that can be required for particular applications. 1.4 This Standard specifies the following categories of cables: Clause 5 / Category - Thermoset and PUR multiconductor round cables for mining and general applications rated 5 kV – 35 kV - Types: SHD, SHD-BGC (balanced ground check), SHD-GC Clause 6 / Category - Thermoset and PUR multiconductor round cables for mining and general applications rated 2 kV - Types: W, G, G-BGC (balanced ground check), G-GC, SHC-GC, SHD, SHD-BGC (balanced ground check), SHD-GC, SHD-R Clause 7 / Category - Thermoset single-conductor cables for mining and general applications rated 2 kV – 35 kV - Types: W, SH Clause 8 / Category - Thermoset two- and three-conductor flat cables for mining and general applications rated 2 kV — Suitable for underground applications only - Types: G, G-GC, W Clause 9 / Category - Thermoset three-conductor round cables with a central bonding conductor for underground coal mining applications rated 2 kV – 5 kV - Types: SHD-PCG Clause 10 / Category - Arc-welding cable Clause 11 / Category - Single-conductor portable power cable rated 600 V - Types: PPC, PPC/TPE Clause 12 / Category - Single and multiconductor portable power cables for general applications rated 600 V – 2 kV - Types: PPC, PPC/TPE Clause 13 / Category - Flexible multiconductor cable for use with cranes and hoists rated 600 V (festoon cable) Clause 14 / Category - Variable frequency drive cable, multiconductor, round, for mining and general applications rated 2 kV – 15 kV - Types: VFD, VFD-GC, VFD-BGC (balanced ground check) Clause 15 / Category - DLO (diesel locomotive) cable, single conductor, used for portable and general permanent applications rated 2 kV Clause 16 / Category - Thermoset and PUR multiconductor round special construction cables for mining and general applications rated 2 kV – 35 kV - Types: SHD-SP, SHD-BGC-SP (balanced ground check), SHD-GC-SP 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 The values given in SI units are the units of record for the purposes of this Standard.

Previous Editions

Can’t find what you are looking for?

Please contact us at: