
CSA C22.2 NO. 80601-2-85:21 (R2026)
CSA C22.2 NO. 80601-2-85:21 (R2026) – Medical electrical equipment — Part 2-85: Particular requirements for the basic safety and essential performance of cerebral tissue oximeter equipment (Adopted ISO 80601-2-85:2021, first edition, 2021-03, with Canadian deviations)
CDN $416.00
Medical electrical equipment — Part 2-85: Particular requirements for the basic safety and essential performance of cerebral tissue oximeter equipment (Adopted ISO 80601-2-85:2021, first edition, 2021-03, with Canadian deviations)
Description
CSA Preface This is the first edition of CSA C22.2 No. 80601-2-85, Medical electrical equipment — Part 2-85: Particular requirements for the basic safety and essential performance of cerebral tissue oximeter equipment , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-85 (first edition, 2021-03). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CSA C22.2 No. 80601-2-85” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object Clause 1 of the general standard applies, except as follows. NOTE The general standard is IEC 60601-:2005+AMD1:2012+AMD2:2020. 201.1.1 * Scope Replacement: This document applies to basic safety and essential performance of cerebral tissue oximeter equipment, that employs light at multiple wavelengths to derive a quantitative measure of oxygen saturation of haemoglobin within the volume of tissue sampled under the probe attached to the head. The cerebral tissue oximeter equipment can be based on continuous light, frequency domain or time domain technologies. This document applies to ME equipment used in a hospital environment as well as when used outside the hospital environment, such as in ambulances and air transport. Additional standards may apply to ME equipment for those environments of use. NOTE 1 Cerebral tissue oximeters are sometimes referred to as near infrared spectroscopy equipment in medical literature. Not included within the scope of this document are: – invasive tissue or vascular oximeters; – oximeters that require a blood sample from the patient; – equipment measuring dissolved oxygen; – ME equipment, or part thereof, that measures path-length-dependent haemoglobin change. The requirements for functional near-infrared spectroscopy equipment are found in ISO 80601-2-71[4]; – ME equipment, or part thereof, that measures arterial saturation based on pulsatile changes in tissue optical properties (SpO2). The requirements for pulse oximeter equipment are found in ISO 80601-2-61 [3]; – ME equipment, or any part thereof, that claims to monitor tissue in parts of the body other than the head. This document also applies to cerebral tissue oximeter equipment, including cerebral tissue oximeter monitors, cerebral tissue oximeter probes and probe cable extenders, that have been remanufactured. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 201.11 and in 201.7.2.13 and 201.8.4.1 of the general standard. NOTE 2 See also 4.2 of the general standard. This document can also be applied to ME equipment and their accessories used for compensation or alleviation of disease, injury or disability. This document is not applicable to remote or slave (secondary) equipment that displays StO2 values that are located outside of the patient environment. NOTE 3 ME equipment that provides selection between diagnostic and monitoring functions is expected to meet the requirements of the appropriate document when configured for that function. 201.1.2 Object Replacement: The object of this document is to establish particular basic safety and essential performance requirements for cerebral tissue oximeter equipment [as defined in 201.3.202] and its accessories. NOTE 1 Accessories are included because the combination of the cerebral tissue oximeter monitor and the accessories needs to be adequately safe. Accessories can have a significant impact on the basic safety or essential performance of cerebral tissue oximeter equipment. NOTE 2 This document has been prepared to address the relevant International Medical Device Regulators Forum (IMDRF) essential principles and labelling guidances as indicated in Annex JJ. NOTE 3 This document has been prepared to address the relevant essential principles of safety and performance of ISO 16142-1:2016 as indicated in Annex KK. NOTE 4 This document has been prepared to address the relevant general safety and performance requirements of European regulation (EU) 2017/745 [20] as indicated in Annex LL.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
130
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the first edition of CSA C22.2 No. 80601-2-85, Medical electrical equipment — Part 2-85: Particular requirements for the basic safety and essential performance of cerebral tissue oximeter equipment , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-85 (first edition, 2021-03). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CSA C22.2 No. 80601-2-85” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object Clause 1 of the general standard applies, except as follows. NOTE The general standard is IEC 60601-:2005+AMD1:2012+AMD2:2020. 201.1.1 * Scope Replacement: This document applies to basic safety and essential performance of cerebral tissue oximeter equipment, that employs light at multiple wavelengths to derive a quantitative measure of oxygen saturation of haemoglobin within the volume of tissue sampled under the probe attached to the head. The cerebral tissue oximeter equipment can be based on continuous light, frequency domain or time domain technologies. This document applies to ME equipment used in a hospital environment as well as when used outside the hospital environment, such as in ambulances and air transport. Additional standards may apply to ME equipment for those environments of use. NOTE 1 Cerebral tissue oximeters are sometimes referred to as near infrared spectroscopy equipment in medical literature. Not included within the scope of this document are: - invasive tissue or vascular oximeters; - oximeters that require a blood sample from the patient; - equipment measuring dissolved oxygen; - ME equipment, or part thereof, that measures path-length-dependent haemoglobin change. The requirements for functional near-infrared spectroscopy equipment are found in ISO 80601-2-71[4]; - ME equipment, or part thereof, that measures arterial saturation based on pulsatile changes in tissue optical properties (SpO2). The requirements for pulse oximeter equipment are found in ISO 80601-2-61 [3]; - ME equipment, or any part thereof, that claims to monitor tissue in parts of the body other than the head. This document also applies to cerebral tissue oximeter equipment, including cerebral tissue oximeter monitors, cerebral tissue oximeter probes and probe cable extenders, that have been remanufactured. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 201.11 and in 201.7.2.13 and 201.8.4.1 of the general standard. NOTE 2 See also 4.2 of the general standard. This document can also be applied to ME equipment and their accessories used for compensation or alleviation of disease, injury or disability. This document is not applicable to remote or slave (secondary) equipment that displays StO2 values that are located outside of the patient environment. NOTE 3 ME equipment that provides selection between diagnostic and monitoring functions is expected to meet the requirements of the appropriate document when configured for that function. 201.1.2 Object Replacement: The object of this document is to establish particular basic safety and essential performance requirements for cerebral tissue oximeter equipment [as defined in 201.3.202] and its accessories. NOTE 1 Accessories are included because the combination of the cerebral tissue oximeter monitor and the accessories needs to be adequately safe. Accessories can have a significant impact on the basic safety or essential performance of cerebral tissue oximeter equipment. NOTE 2 This document has been prepared to address the relevant International Medical Device Regulators Forum (IMDRF) essential principles and labelling guidances as indicated in Annex JJ. NOTE 3 This document has been prepared to address the relevant essential principles of safety and performance of ISO 16142-1:2016 as indicated in Annex KK. NOTE 4 This document has been prepared to address the relevant general safety and performance requirements of European regulation (EU) 2017/745 [20] as indicated in Annex LL.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart -

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart -

CSA E61347-1:24 – Lamp controlgear – Part 1: General and safety requirements (Adopted IEC 61347-1:2015, edition 3:2015 consolidated with amendment 1:2017, with Canadian deviations) | Appareillages de lampes – Partie 1 : Exigences générales et exigences de sécurité (norme IEC 61347-1:2015 adoptée, édition 3:2015 consolidée par l’amendement 1:2017), avec exigences propres au Canada)
CDN $907.00 Add to cart







