
CSA C22.2 NO. 80601-2-79:20 (R2025)
CSA C22.2 NO. 80601-2-79:20 (R2025) – Medical electrical equipment — Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment (Adopted ISO 80601-2-79:2018, first edition, 2018-07, with Canadian deviations)
CDN $405.00
Medical electrical equipment — Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment (Adopted ISO 80601-2-79:2018, first edition, 2018-07, with Canadian deviations)
Description
CSA Preface This is the first edition of CSA C22.2 No. 80601-2-79, Medical electrical equipment — Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment, which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-79 (first edition, 2018-07). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC Standard 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object IEC 60601-1:2005+AMD1:2012, Clause 1, applies, except as follows: 201.1.1 * Scope Replacement: This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of VENTILATORY SUPPORT EQUIPMENT, as defined in 201.3.205, for VENTILATORY IMPAIRMENT, as defined in 201.3.202, hereafter also referred to as ME EQUIPMENT, in combination with its ACCESSORIES: — intended for use in the HOME HEALTHCARE ENVIRONMENT; — intended for use by a LAY OPERATOR; and — intended for use with PATIENTS who have VENTILATORY IMPAIRMENT, the most fragile of these PATIENTS, would not likely experience injury with the loss of this artificial ventilation; and — not intended for PATIENTS who are dependent on artificial ventilation for their immediate life support. EXAMPLE 1 PATIENTS with mild to moderate chronic obstructive pulmonary disease (COPD). NOTE 1 In the HOME HEALTHCARE ENVIRONMENT, the SUPPLY MAINS is often not reliable. NOTE 2 Such VENTILATORY SUPPORT EQUIPMENT can also be used in non-critical care applications of professional health care facilities. This document is also applicable to those ACCESSORIES intended by their MANUFACTURER to be connected to the BREATHING SYSTEM of VENTILATORY SUPPORT EQUIPMENT for VENTILATORY IMPAIRMENT, where the characteristics of those ACCESSORIES can affect the BASIC SAFETY or ESSENTIAL PERFORMANCE of the VENTILATORY SUPPORT EQUIPMENT for VENTILATORY IMPAIRMENT. EXAMPLE 2 Breathing sets, connectors, water traps, expiratory valve, HUMIDIFIER, BREATHING SYSTEM FILTER, external electrical power source, DISTRIBUTED ALARM SYSTEM. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD1:2012, 7.2.13 and 8.4.1. NOTE 3 Additional information can be found in IEC 60601-1:2005 +AMD1:2012, 4.2. This document does not specify the requirements for: — VENTILATORS or ACCESSORIES for VENTILATOR-DEPENDENT PATIENTS intended for critical care applications, which are given in ISO 80601-2-12; — VENTILATORS or ACCESSORIES intended for anaesthetic applications, which are given in ISO 80601-2-13[4]; — VENTILATORS or ACCESSORIES intended for the emergency medical services environment, which are given in ISO 80601-2-84 [5] 4, the future replacement for ISO 10651-3 [6]; — VENTILATORS or ACCESSORIES intended for VENTILATOR-DEPENDENT PATIENTS in the HOME HEALTHCARE ENVIRONMENT, which are given in ISO 80601-2-72; — VENTILATORY SUPPORT EQUIPMENT or ACCESSORIES intended for VENTILATORY INSUFFICIENCY, which are given in ISO 80601-2-80[1]; — sleep apnoea therapy ME EQUIPMENT, which are given in ISO 80601-2-70 [7]; — continuous positive airway pressure (CPAP) ME EQUIPMENT; — high-frequency jet VENTILATORS (HFJVs); — high-frequency oscillatory VENTILATORS (HFOVs)[8]; — oxygen therapy constant flow ME EQUIPMENT; — cuirass or “iron-lung” ventilation equipment. This document is a document in the IEC 60601 and IEC/ISO 80601 series of documents. 201.1.2 Object Replacement: The object of this document is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for VENTILATORY SUPPORT EQUIPMENT, as defined in 201.3.205, and its ACCESSORIES. NOTE ACCESSORIES are included because the combination of the VENTILATORY SUPPORT EQUIPMENT and the ACCESSORIES needs to be adequately safe. ACCESSORIES can have a significant impact on the BASIC SAFETY or ESSENTIAL PERFORMANCE of the VENTILATORY SUPPORT EQUIPMENT.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
98
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the first edition of CSA C22.2 No. 80601-2-79, Medical electrical equipment — Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment, which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-79 (first edition, 2018-07). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC Standard 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object IEC 60601-1:2005+AMD1:2012, Clause 1, applies, except as follows: 201.1.1 * Scope Replacement: This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of VENTILATORY SUPPORT EQUIPMENT, as defined in 201.3.205, for VENTILATORY IMPAIRMENT, as defined in 201.3.202, hereafter also referred to as ME EQUIPMENT, in combination with its ACCESSORIES: — intended for use in the HOME HEALTHCARE ENVIRONMENT; — intended for use by a LAY OPERATOR; and — intended for use with PATIENTS who have VENTILATORY IMPAIRMENT, the most fragile of these PATIENTS, would not likely experience injury with the loss of this artificial ventilation; and — not intended for PATIENTS who are dependent on artificial ventilation for their immediate life support. EXAMPLE 1 PATIENTS with mild to moderate chronic obstructive pulmonary disease (COPD). NOTE 1 In the HOME HEALTHCARE ENVIRONMENT, the SUPPLY MAINS is often not reliable. NOTE 2 Such VENTILATORY SUPPORT EQUIPMENT can also be used in non-critical care applications of professional health care facilities. This document is also applicable to those ACCESSORIES intended by their MANUFACTURER to be connected to the BREATHING SYSTEM of VENTILATORY SUPPORT EQUIPMENT for VENTILATORY IMPAIRMENT, where the characteristics of those ACCESSORIES can affect the BASIC SAFETY or ESSENTIAL PERFORMANCE of the VENTILATORY SUPPORT EQUIPMENT for VENTILATORY IMPAIRMENT. EXAMPLE 2 Breathing sets, connectors, water traps, expiratory valve, HUMIDIFIER, BREATHING SYSTEM FILTER, external electrical power source, DISTRIBUTED ALARM SYSTEM. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD1:2012, 7.2.13 and 8.4.1. NOTE 3 Additional information can be found in IEC 60601-1:2005 +AMD1:2012, 4.2. This document does not specify the requirements for: — VENTILATORS or ACCESSORIES for VENTILATOR-DEPENDENT PATIENTS intended for critical care applications, which are given in ISO 80601-2-12; — VENTILATORS or ACCESSORIES intended for anaesthetic applications, which are given in ISO 80601-2-13[4]; — VENTILATORS or ACCESSORIES intended for the emergency medical services environment, which are given in ISO 80601-2-84 [5] 4, the future replacement for ISO 10651-3 [6]; — VENTILATORS or ACCESSORIES intended for VENTILATOR-DEPENDENT PATIENTS in the HOME HEALTHCARE ENVIRONMENT, which are given in ISO 80601-2-72; — VENTILATORY SUPPORT EQUIPMENT or ACCESSORIES intended for VENTILATORY INSUFFICIENCY, which are given in ISO 80601-2-80[1]; — sleep apnoea therapy ME EQUIPMENT, which are given in ISO 80601-2-70 [7]; — continuous positive airway pressure (CPAP) ME EQUIPMENT; — high-frequency jet VENTILATORS (HFJVs); — high-frequency oscillatory VENTILATORS (HFOVs)[8]; — oxygen therapy constant flow ME EQUIPMENT; — cuirass or "iron-lung" ventilation equipment. This document is a document in the IEC 60601 and IEC/ISO 80601 series of documents. 201.1.2 Object Replacement: The object of this document is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for VENTILATORY SUPPORT EQUIPMENT, as defined in 201.3.205, and its ACCESSORIES. NOTE ACCESSORIES are included because the combination of the VENTILATORY SUPPORT EQUIPMENT and the ACCESSORIES needs to be adequately safe. ACCESSORIES can have a significant impact on the BASIC SAFETY or ESSENTIAL PERFORMANCE of the VENTILATORY SUPPORT EQUIPMENT.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA G164:26 – Galvanizing of irregularly shaped articles
CDN $142.00 Add to cart -

CSA SPE-1000:25 – Model Code for the field evaluation of electrical equipment
CDN $378.00 Add to cart -

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

CSA G12:14 (R2024) – Zinc-coated steel wire strand
CDN $136.00 Add to cart







