CSA C22.2 NO. 80601-2-55:21 (R2026) – Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors (Adopted ISO 80601-2-55:2018, second edition, 2018-02, with Canadian deviations)
CDN $398.00
Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors (Adopted ISO 80601-2-55:2018, second edition, 2018-02, with Canadian deviations)
Description
CSA Preface This is the second edition of CSA C22.2 No. 80601-2-55, Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-55 (second edition, 2018-02). It supersedes the previous edition, published in 2014 as CAN/CSA-C22.2 No. 80601-2-55 (adopted ISO 80601-2-55:2011). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CSA C22.2 No. 80601-2-55” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object IEC 60601-1:2005+Amd 1:2012, Clause 1 applies, except as follows: 201.1.1 *Scope IEC 60601-1:2005+Amd 1:2012, 1.1 is replaced by: This document specifies particular requirements for the BASIC SAFETY and ESSENTIAL PERFORMANCE of a RESPIRATORY GAS MONITOR (RGM), hereafter referred to as ME EQUIPMENT, intended for CONTINUOUS OPERATION for use with a PATIENT. This document specifies requirements for — anaesthetic gas monitoring, — carbon dioxide monitoring, and — oxygen monitoring. NOTE 1 An RGM can be either stand-alone ME EQUIPMENT or integrated into other equipment, e.g. an anaesthetic workstation or a ventilator. This document is not applicable to an RGM intended for use with flammable anaesthetic agents. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+Amd 1:2012, 7.2.13 and 8.4.1. NOTE 2 Additional information can be found in IEC 60601-1:2005+Amd 1:2012, 4.2. 201.1.2 Object IEC 60601-1:2005+Amd 1:2012, 1.2 is replaced by: The object of this document is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for an RGM (as defined in 201.3.210) and its ACCESSORIES. NOTE ACCESSORIES are included because the combination of the RGM and the ACCESSORIES needs to be safe. ACCESSORIES can have a significant impact on the BASIC SAFETY and ESSENTIAL PERFORMANCE of an RGM.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
81
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CSA C22.2 No. 80601-2-55, Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-55 (second edition, 2018-02). It supersedes the previous edition, published in 2014 as CAN/CSA-C22.2 No. 80601-2-55 (adopted ISO 80601-2-55:2011). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CSA C22.2 No. 80601-2-55” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health and Well-being. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object IEC 60601-1:2005+Amd 1:2012, Clause 1 applies, except as follows: 201.1.1 *Scope IEC 60601-1:2005+Amd 1:2012, 1.1 is replaced by: This document specifies particular requirements for the BASIC SAFETY and ESSENTIAL PERFORMANCE of a RESPIRATORY GAS MONITOR (RGM), hereafter referred to as ME EQUIPMENT, intended for CONTINUOUS OPERATION for use with a PATIENT. This document specifies requirements for — anaesthetic gas monitoring, — carbon dioxide monitoring, and — oxygen monitoring. NOTE 1 An RGM can be either stand-alone ME EQUIPMENT or integrated into other equipment, e.g. an anaesthetic workstation or a ventilator. This document is not applicable to an RGM intended for use with flammable anaesthetic agents. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+Amd 1:2012, 7.2.13 and 8.4.1. NOTE 2 Additional information can be found in IEC 60601-1:2005+Amd 1:2012, 4.2. 201.1.2 Object IEC 60601-1:2005+Amd 1:2012, 1.2 is replaced by: The object of this document is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for an RGM (as defined in 201.3.210) and its ACCESSORIES. NOTE ACCESSORIES are included because the combination of the RGM and the ACCESSORIES needs to be safe. ACCESSORIES can have a significant impact on the BASIC SAFETY and ESSENTIAL PERFORMANCE of an RGM.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.2-2017/CSA C293.2:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—Application guide for design, installation, testing, commissioning, and maintenance
CDN $158.00 Add to cart -

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CSA TS-117:23 – National technical specification for terminology for the decentralized energy industry in Canada
CDN $79.00 Add to cart