Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 51:26

CSA C22.2 NO. 51:26 – Armoured cables

CDN $331.00

Armoured cables

SKU: 2432461 Categories: ,

Description

Preface This is the fourteenth edition of CSA C22.2 No. 51, Armoured cables , one of a series of Standards issued by CSA Group under the Canadian Electrical Code, Part II. It supersedes the previous editions published in 2020, 2014, 2009, 1995, 1989, 1981, 1968, 1961, 1957, 1953, 1949, 1941, and 1938. The main changes to this edition include the following: a) updating the requirements for length of lay in Clause 5.3.1and Table 15; b) adding the requirements for PCS construction to Type ACWU90 in Clauses 5.1.1.2, 5.1.1.3, 5.1.4.3, 7.1.3, and 7.2; c) updating the requirements and compliance criteria for the electrical resistance test in Clause 6.1.1.1; d) updating the requirements for “FT4” and halogen-free markings on finished products, coil, and reels in Clauses 7.1.2, 7.1.3, and 7.2; e) updating the requirements on colour coding on insulated conductors in Table 8; and f) updating the tensile strength and elongation retention values after aging and oil immersion in Table 18. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Metal Clad Cables, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for single- and multi-conductor insulated cables having metallic interlocked armour without an overall jacket (Type AC90 or ACG90) or with an overall jacket (Type ACWU90 or ACGWU90) that are intended for installation in accordance with CSA C22.1, Canadian Electrical Code, Part I, on systems having nominal voltages of 2000 V and less. ACG90 and ACGWU90 apply to multi-conductor cables only. ACG90 and ACGWU90 shall have voltages of 600 V and less. 1.2 This Standard specifies requirements for cables having insulated conductors in sizes 18 AWG to 2000 kcmil. The maximum cable temperature rating is 90 °C. Note: See Annex B for a summary of the cable types covered by this Standard and corresponding constructions, voltage ratings, and the number and size of conductors for the types to which this Standard applies. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

69

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the fourteenth edition of CSA C22.2 No. 51, Armoured cables , one of a series of Standards issued by CSA Group under the Canadian Electrical Code, Part II. It supersedes the previous editions published in 2020, 2014, 2009, 1995, 1989, 1981, 1968, 1961, 1957, 1953, 1949, 1941, and 1938. The main changes to this edition include the following: a) updating the requirements for length of lay in Clause 5.3.1and Table 15; b) adding the requirements for PCS construction to Type ACWU90 in Clauses 5.1.1.2, 5.1.1.3, 5.1.4.3, 7.1.3, and 7.2; c) updating the requirements and compliance criteria for the electrical resistance test in Clause 6.1.1.1; d) updating the requirements for "FT4" and halogen-free markings on finished products, coil, and reels in Clauses 7.1.2, 7.1.3, and 7.2; e) updating the requirements on colour coding on insulated conductors in Table 8; and f) updating the tensile strength and elongation retention values after aging and oil immersion in Table 18. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Metal Clad Cables, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for single- and multi-conductor insulated cables having metallic interlocked armour without an overall jacket (Type AC90 or ACG90) or with an overall jacket (Type ACWU90 or ACGWU90) that are intended for installation in accordance with CSA C22.1, Canadian Electrical Code, Part I, on systems having nominal voltages of 2000 V and less. ACG90 and ACGWU90 apply to multi-conductor cables only. ACG90 and ACGWU90 shall have voltages of 600 V and less. 1.2 This Standard specifies requirements for cables having insulated conductors in sizes 18 AWG to 2000 kcmil. The maximum cable temperature rating is 90 °C. Note: See Annex B for a summary of the cable types covered by this Standard and corresponding constructions, voltage ratings, and the number and size of conductors for the types to which this Standard applies. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: