CSA C22.2 NO. 292:18 (R2022)
CSA C22.2 NO. 292:18 (R2022) – Dc arc fault protection for photovoltaic applications
CDN $417.00
Dc arc fault protection for photovoltaic applications
Description
Preface This is the first edition of CSA C22.2 No. 292, Dc arc fault protection for photovoltaic applications, one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is intended to replace the requirements previously contained in CSA TIL M-07. Arc fault protective devices are often embodied in combination with another device. As such, the user of this Standard may need to reference additional requirements as found in CSA C22.2 No. 5, CSA C22.2 No. 144.1, CSA C22.2 No. 21, CSA C22.2 No. 42, or elsewhere, as applicable. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Arc Fault Protective Devices for Photovoltaics under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to dc arc fault protective devices (DC-AFPDs) and devices incorporating arc fault circuit protection intended for use in direct current circuits in photovoltaic (PV) systems having a maximum voltage rating of 1000 V dc and intended for installation in accordance with the rules of the Canadian Electrical Code, Part I. 1.2 This Standard contains construction, test, and marking requirements for DC-AFPDs and is designed to be used in conjunction with CSA CAN/CSA-C22.2 No. 5, CSA C22.2 No. 144.1, CSA C22.2 No. 305, and CSA C22.2 No. 107.1 as applicable. 1.3 A DC-AFPD is intended to detect and mitigate the effects of arcing faults that can pose a risk of fire ignition under certain conditions if the arcing persists. A DC-AFPD is not intended to detect glowing connections. 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
50
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of CSA C22.2 No. 292, Dc arc fault protection for photovoltaic applications, one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is intended to replace the requirements previously contained in CSA TIL M-07. Arc fault protective devices are often embodied in combination with another device. As such, the user of this Standard may need to reference additional requirements as found in CSA C22.2 No. 5, CSA C22.2 No. 144.1, CSA C22.2 No. 21, CSA C22.2 No. 42, or elsewhere, as applicable. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Arc Fault Protective Devices for Photovoltaics under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to dc arc fault protective devices (DC-AFPDs) and devices incorporating arc fault circuit protection intended for use in direct current circuits in photovoltaic (PV) systems having a maximum voltage rating of 1000 V dc and intended for installation in accordance with the rules of the Canadian Electrical Code, Part I. 1.2 This Standard contains construction, test, and marking requirements for DC-AFPDs and is designed to be used in conjunction with CSA CAN/CSA-C22.2 No. 5, CSA C22.2 No. 144.1, CSA C22.2 No. 305, and CSA C22.2 No. 107.1 as applicable. 1.3 A DC-AFPD is intended to detect and mitigate the effects of arcing faults that can pose a risk of fire ignition under certain conditions if the arcing persists. A DC-AFPD is not intended to detect glowing connections. 1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA TS-117:23 – National technical specification for terminology for the decentralized energy industry in Canada
CDN $79.00 Add to cart -

CSA G164:26 – Galvanizing of irregularly shaped articles
CDN $142.00 Add to cart -

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart