Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 286:23

CSA C22.2 NO. 286:23 – Industrial control panels and assemblies

CDN $559.00

Industrial control panels and assemblies

SKU: 2430558 Categories: ,

Description

Preface This is the third edition of CSA C22.2 No. 286, Industrial control panels and assemblies , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2017 and 2015. The major changes to this edition include a) expansion of requirements for connection means; b) additional requirements for ferrules and pigtail adapters; c) clarifications for requirements for Class 2 (non-safety control devices) components; d) additional compliance criteria for panels and assemblies for use outside of the assumed 0–40° C ambient range; e) expansion of the short-circuit current rating (SCCR) determination criteria; f) revisions to required SCCR markings; g) removal of motor control centre requirements; and h) addition of strain relief and abnormal operations tests. In addition, numerous edits have been performed throughout the document to provide additional information and clarify certain requirements. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CSA C22.2 No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Industrial Control under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to industrial control panels and assemblies rated at not more than 1500 V, intended to be installed and used in non-hazardous locations in accordance with the rules of the Canadian Electrical Code, Part I. Notes: 1) Examples of industrial control panels and assemblies covered by this Standard include motor control panels, process control equipment panels, heating panels, programmable control panels, heating and cooling equipment control panels, etc. 2) The term “control” as used throughout this Standard applies to both starters and controllers. 3) Electrical instruments that can be included as part of control equipment such as meters, are not covered by this Standard. 1.2 The industrial control panels and assemblies covered by this Standard are intended for use in an ambient temperature of 0 to 40 °C. Additional investigation of the equipment will be required when equipment is to be used in an ambient temperature outside of this range. 1.3 This Standard does not apply to equipment covered by other CSA Standards, such as but not limited to a) power supplies; b) automatic transfer switches; c) elevator equipment; d) enclosed switches; e) switchgear; f) line isolation monitors; g) panelboards and custom panelboards; h) hazardous location equipment; i) hydro-massage equipment; j) power factor correction capacitor banks; k) fire pump controllers; l) assemblies of equipment intended solely for the distribution of power; and m) motor control centre units and sections. 1.4 This Standard does not apply to external loads controlled by the industrial control panels and assemblies. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

109

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the third edition of CSA C22.2 No. 286, Industrial control panels and assemblies , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2017 and 2015. The major changes to this edition include a) expansion of requirements for connection means; b) additional requirements for ferrules and pigtail adapters; c) clarifications for requirements for Class 2 (non-safety control devices) components; d) additional compliance criteria for panels and assemblies for use outside of the assumed 0–40° C ambient range; e) expansion of the short-circuit current rating (SCCR) determination criteria; f) revisions to required SCCR markings; g) removal of motor control centre requirements; and h) addition of strain relief and abnormal operations tests. In addition, numerous edits have been performed throughout the document to provide additional information and clarify certain requirements. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CSA C22.2 No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Industrial Control under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to industrial control panels and assemblies rated at not more than 1500 V, intended to be installed and used in non-hazardous locations in accordance with the rules of the Canadian Electrical Code, Part I. Notes: 1) Examples of industrial control panels and assemblies covered by this Standard include motor control panels, process control equipment panels, heating panels, programmable control panels, heating and cooling equipment control panels, etc. 2) The term “control” as used throughout this Standard applies to both starters and controllers. 3) Electrical instruments that can be included as part of control equipment such as meters, are not covered by this Standard. 1.2 The industrial control panels and assemblies covered by this Standard are intended for use in an ambient temperature of 0 to 40 °C. Additional investigation of the equipment will be required when equipment is to be used in an ambient temperature outside of this range. 1.3 This Standard does not apply to equipment covered by other CSA Standards, such as but not limited to a) power supplies; b) automatic transfer switches; c) elevator equipment; d) enclosed switches; e) switchgear; f) line isolation monitors; g) panelboards and custom panelboards; h) hazardous location equipment; i) hydro-massage equipment; j) power factor correction capacitor banks; k) fire pump controllers; l) assemblies of equipment intended solely for the distribution of power; and m) motor control centre units and sections. 1.4 This Standard does not apply to external loads controlled by the industrial control panels and assemblies. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.