
CSA C22.2 NO. 272:26
CSA C22.2 NO. 272:26 – Wind turbine electrical systems
CDN $299.00
Wind turbine electrical systems
Description
Preface This is the third edition of CSA C22.2 No. 272, Wind turbine electrical systems . It supersedes the previous editions published in 2020 and 2014. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The following are the major changes to this edition: a) updated requirements regarding liquid-filled transformers (see Clause 4.2.11.2); b) added standards to the requirements for dry-type transformers (see Clause 4.2.11.3); c) added standards to the requirements for converters/inverters (see Clause 4.2.12); d) added standards to the requirements for motors and generators (see Clause 4.2.20); e) added standards to the requirements for emergency stop buttons (see Clause 9.7.2); f) updated requirements regarding ampacity (see Clause 10.8.1.3); and g) updated requirements regarding electrical qualification of climb assists (see Clause 13.4.1). For general information on the standards of the Canadian Electrical Code, Part II, see the Preface of CSA C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Wind Turbines — Electrical Qualification, under the jurisdiction of the Technical Committee on Wind Turbines and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard applies to complete wind turbine electrical systems and associated electrical equipment intended for connection at not more than 46 kV, and intended for use in accordance with the Canadian Electrical Code, Part I. Products covered by the scope of this Standard are subject to the requirements of CSA C22.2 No. 0. 1.2 Application This Standard applies to wind turbines of all sizes. 1.3 Exclusions This Standard does not apply to performance with respect to grid codes or to power performance of wind turbines. Note: Information on test methods for power performance of wind turbines can be found in CAN/CSA-IEC 61400-12-1 and IEC 61400-12-2. 1.4 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
72
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the third edition of CSA C22.2 No. 272, Wind turbine electrical systems . It supersedes the previous editions published in 2020 and 2014. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The following are the major changes to this edition: a) updated requirements regarding liquid-filled transformers (see Clause 4.2.11.2); b) added standards to the requirements for dry-type transformers (see Clause 4.2.11.3); c) added standards to the requirements for converters/inverters (see Clause 4.2.12); d) added standards to the requirements for motors and generators (see Clause 4.2.20); e) added standards to the requirements for emergency stop buttons (see Clause 9.7.2); f) updated requirements regarding ampacity (see Clause 10.8.1.3); and g) updated requirements regarding electrical qualification of climb assists (see Clause 13.4.1). For general information on the standards of the Canadian Electrical Code, Part II, see the Preface of CSA C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Wind Turbines — Electrical Qualification, under the jurisdiction of the Technical Committee on Wind Turbines and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard applies to complete wind turbine electrical systems and associated electrical equipment intended for connection at not more than 46 kV, and intended for use in accordance with the Canadian Electrical Code, Part I. Products covered by the scope of this Standard are subject to the requirements of CSA C22.2 No. 0. 1.2 Application This Standard applies to wind turbines of all sizes. 1.3 Exclusions This Standard does not apply to performance with respect to grid codes or to power performance of wind turbines. Note: Information on test methods for power performance of wind turbines can be found in CAN/CSA-IEC 61400-12-1 and IEC 61400-12-2. 1.4 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA W212:25 – Temporary flood protection barrier performance testing for Canadian climates
CDN $103.00 Add to cart -

CSA TS-888:26 – Guideline for the installation and energy performance commissioning of residential behind-the-meter battery energy storage systems
CDN $236.00 Add to cart -

CSA W208:20 (R2025) – Erosion and sediment control installation and maintenance
CDN $79.00 Add to cart -

CSA TS-006:25 – Water distribution and wastewater collection systems in northern regions
CDN $158.00 Add to cart







