Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 26:13 (R2023)

CSA C22.2 NO. 26:13 (R2023) – Construction and test of wireways, auxiliary gutters and associated fittings

CDN $170.00

Construction and test of wireways, auxiliary gutters and associated fittings

SKU: 2422683 Categories: ,

Description

Preface This is the third edition of C22.2 No. 26, Construction and test of wireways, auxiliary gutters, and associated fittings . It supersedes the previous editions published in 1952 and 1935. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements – Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Specialized Wiring Systems under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to the following metal enclosures, for potentials up to and including 600 volts between conductors and ground, designed to be employed in accordance with the rules of the Canadian Electrical Code, Part I: a) wireways for insulated wires and cables; b) auxiliary gutters (for insulated wires and cables) for use at switchboards, meter centres, etc.; and c) associated fittings for completing wireway systems. 1.2 These enclosures are intended for use in installations, in commercial, industrial, and some of the larger domestic applications, in non-hazardous locations, and where they are not likely to be subjected to severe mechanical damage. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

20

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the third edition of C22.2 No. 26, Construction and test of wireways, auxiliary gutters, and associated fittings . It supersedes the previous editions published in 1952 and 1935. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Specialized Wiring Systems under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to the following metal enclosures, for potentials up to and including 600 volts between conductors and ground, designed to be employed in accordance with the rules of the Canadian Electrical Code, Part I: a) wireways for insulated wires and cables; b) auxiliary gutters (for insulated wires and cables) for use at switchboards, meter centres, etc.; and c) associated fittings for completing wireway systems. 1.2 These enclosures are intended for use in installations, in commercial, industrial, and some of the larger domestic applications, in non-hazardous locations, and where they are not likely to be subjected to severe mechanical damage. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: