
CSA C22.2 NO. 206:25
CSA C22.2 NO. 206:25 – Lighting poles
CDN $394.00
Lighting poles
Description
Preface This is the fifth edition of CSA C22.2 No. 206, Lighting poles , part of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2022, 2017, 2013, and 1987. The following are the major changes to this edition: a) consolidation of the scope and updating of the maximum voltage rating (see Clause 1); b) addition of general electrical component requirements (see Clause 4.3); c) revision for the support of electrical equipment to include additional equipment (see Clause 5.4); d) clarification of bonding requirements (see Clause 6.1and Annex A); e) additional structural requirements for poles intended to support telecom equipment (see Clause 7.1); and f) clarification and update of the requirements for lighting poles equipped with electrical components (see Annex B). The purpose of this Standard is to ensure, through the provision of minimum requirements for construction, the mechanical strength aspects, electrical features, and design-load capabilities of lighting poles. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Lighting Products, under the jurisdiction of the Technical Committee on Consumer and Commercial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Application 1.1.1 This Standard applies to free-standing poles of ferrous metal, aluminum, polymeric, concrete, fibre-reinforced structures, and wood, and to their accessories, for use in the support of lighting equipment having ratings of 1000 V and less and intended to be installed in the commercial and industrial nonhazardous locations in accordance with CSA C22.1, Canadian Electrical Code, Part I. 1.1.2 This Standard includes the electrical features of poles as well as to the mechanical strength aspects and the ability to support their design loads. The poles may also serve as supports for aerial conductors, photovoltaic (PV) modules, wind turbines used to supply the lighting equipment, smart city communication, and data transmission devices, and, in the case of concrete or metal poles, provide wireways for conductors entering the poles. This Standard does not apply to the erection of poles or the installation of accessories on site. Notes: 1) Lighting equipment includes luminaires, electric signs, and traffic lights. 2) Lighting poles for residential applications less than 4 m in height may be evaluated to the requirements of CSA C22.2 No. 250.0 for electrical safety only and be marked NOT EVALUATED FOR STRUCTURAL STRENGTH/N’A PAS ÉTÉ ÉVALUÉ QUANT À LA RÉSISTANCE STRUCTURALE. 1.2 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
34
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the fifth edition of CSA C22.2 No. 206, Lighting poles , part of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2022, 2017, 2013, and 1987. The following are the major changes to this edition: a) consolidation of the scope and updating of the maximum voltage rating (see Clause 1); b) addition of general electrical component requirements (see Clause 4.3); c) revision for the support of electrical equipment to include additional equipment (see Clause 5.4); d) clarification of bonding requirements (see Clause 6.1and Annex A); e) additional structural requirements for poles intended to support telecom equipment (see Clause 7.1); and f) clarification and update of the requirements for lighting poles equipped with electrical components (see Annex B). The purpose of this Standard is to ensure, through the provision of minimum requirements for construction, the mechanical strength aspects, electrical features, and design-load capabilities of lighting poles. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Lighting Products, under the jurisdiction of the Technical Committee on Consumer and Commercial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Application 1.1.1 This Standard applies to free-standing poles of ferrous metal, aluminum, polymeric, concrete, fibre-reinforced structures, and wood, and to their accessories, for use in the support of lighting equipment having ratings of 1000 V and less and intended to be installed in the commercial and industrial nonhazardous locations in accordance with CSA C22.1, Canadian Electrical Code, Part I. 1.1.2 This Standard includes the electrical features of poles as well as to the mechanical strength aspects and the ability to support their design loads. The poles may also serve as supports for aerial conductors, photovoltaic (PV) modules, wind turbines used to supply the lighting equipment, smart city communication, and data transmission devices, and, in the case of concrete or metal poles, provide wireways for conductors entering the poles. This Standard does not apply to the erection of poles or the installation of accessories on site. Notes: 1) Lighting equipment includes luminaires, electric signs, and traffic lights. 2) Lighting poles for residential applications less than 4 m in height may be evaluated to the requirements of CSA C22.2 No. 250.0 for electrical safety only and be marked NOT EVALUATED FOR STRUCTURAL STRENGTH/N’A PAS ÉTÉ ÉVALUÉ QUANT À LA RÉSISTANCE STRUCTURALE. 1.2 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart -

CSA TS-117:23 – National technical specification for terminology for the decentralized energy industry in Canada
CDN $79.00 Add to cart







