CSA C22.2 NO. 190:14 (R2024)
CSA C22.2 NO. 190:14 (R2024) – Capacitors for power factor correction
CDN $142.00
Capacitors for power factor correction
Description
Preface This is the second edition of CSA C22.2 No. 190, Capacitors for power factor correction , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the first edition published in 1985. Changes to this edition include the insertion of Update 1 (December 1985) and Update 2 (January 1988) and the addition of Clause 10, and Tables 7, 8, 9, and 10. For general information on the Standards of the Canadian Electrical Code, Part II, see the preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Capacitors for Power Factor Correction, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and was formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to indoor or outdoor, open or enclosed, shunt power capacitors and assemblies of shunt power capacitors with associated interconnections and supporting structures, for power factor improvement and other applications on ac power systems having voltages up to 46 kV, designed to be installed in accordance with the Rules of the Canadian Electrical Code, Part I. 1.2 The requirements of this Standard also apply to self-healing capacitor with metallized electrode for use on ac systems having a maximum voltage between phases of 1000 V and less. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
46
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the second edition of CSA C22.2 No. 190, Capacitors for power factor correction , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the first edition published in 1985. Changes to this edition include the insertion of Update 1 (December 1985) and Update 2 (January 1988) and the addition of Clause 10, and Tables 7, 8, 9, and 10. For general information on the Standards of the Canadian Electrical Code, Part II, see the preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Capacitors for Power Factor Correction, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and was formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to indoor or outdoor, open or enclosed, shunt power capacitors and assemblies of shunt power capacitors with associated interconnections and supporting structures, for power factor improvement and other applications on ac power systems having voltages up to 46 kV, designed to be installed in accordance with the Rules of the Canadian Electrical Code, Part I. 1.2 The requirements of this Standard also apply to self-healing capacitor with metallized electrode for use on ac systems having a maximum voltage between phases of 1000 V and less. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart -

CSA TS-117:23 – National technical specification for terminology for the decentralized energy industry in Canada
CDN $79.00 Add to cart -

CAN/CSA-E61965:04 (R2023) – Mechanical safety of cathode ray tubes (Adopted IEC 61965:2003, second edition, 2003-07, with Canadian deviations)
CDN $356.00 Add to cart