Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA/ANSI C22.2 NO. 184.2:20 (R2025)

CSA/ANSI C22.2 NO. 184.2:20 (R2025) – Solid-state controls for lighting systems (SSCLS)

CDN $787.00

Solid-state controls for lighting systems (SSCLS)

SKU: 2426621 Categories: ,

Description

Preface This is the first edition of CSA/ANSI C22.2 No. 184.2, Solid-state controls for lighting systems (SSCLS) . It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Wiring Devices, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 This Standard applies to permanently connected, single or multi-branch circuit, multi-circuit output, solid-state lighting controls rated at 600 V and less, 50 or 60 Hz; single or three phase; with or without overcurrent protection on the load side; with or without integral load switching devices; designed to be used as a complete solid-state lighting control system for the purpose of controlling a single type or multiple types of lighting loads, such as a) incandescent lamps; b) magnetic ballasts; c) fluorescent, compact fluorescent, and electric discharge lamps; d) HID (pilot duty) and electronic ballasts; e) LED and OLED lights and drivers; and f) 0 to 10 V dc analog dimming and intended for installation in accordance with CSA C22.1, Canadian Electrical Code, Part I, and NFPA 70, National Electrical Code (NEC). 1.2 This Standard also applies to SSCLS products mounted in a portable manner. Note: “Mounted on wheels” can include wheel-mounted equipment that can be moved by one person, up to large truck- or trailer-mounted assemblies. Similarly, “mounted on skids” can include equipment that is small enough and light enough to be moved by one person, up to large or heavy units that can only be skidded with larger towing vehicles or lifted and moved with hoists or cranes. 1.3 This Standard applies to ac rated controls for which the load rating does not exceed 40 A per circuit at a maximum of 600 V. 1.4 SSCLS products may include receptacles of configuration 5-15R, 5-20R, and L5-20R, used as lighting load connection points, with access limited to qualified personnel only. 1.5 SSCLS products may include convenience receptacles, mechanical switches, dimming circuits, and other wiring devices on separate circuits. 1.6 SSCLS products may include NC (normally closed) or NO (normally open) contacts for the purpose of controlling other general-use loads rated inductive, resistive, and 2 hp or less. 1.7 SSCLS products may include a Class 2 power supply for the purpose of feeding power to analog or digital inputs, such as sensors. 1.8 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.9 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

71

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA/ANSI C22.2 No. 184.2, Solid-state controls for lighting systems (SSCLS) . It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Wiring Devices, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 This Standard applies to permanently connected, single or multi-branch circuit, multi-circuit output, solid-state lighting controls rated at 600 V and less, 50 or 60 Hz; single or three phase; with or without overcurrent protection on the load side; with or without integral load switching devices; designed to be used as a complete solid-state lighting control system for the purpose of controlling a single type or multiple types of lighting loads, such as a) incandescent lamps; b) magnetic ballasts; c) fluorescent, compact fluorescent, and electric discharge lamps; d) HID (pilot duty) and electronic ballasts; e) LED and OLED lights and drivers; and f) 0 to 10 V dc analog dimming and intended for installation in accordance with CSA C22.1, Canadian Electrical Code, Part I, and NFPA 70, National Electrical Code (NEC). 1.2 This Standard also applies to SSCLS products mounted in a portable manner. Note: "Mounted on wheels" can include wheel-mounted equipment that can be moved by one person, up to large truck- or trailer-mounted assemblies. Similarly, "mounted on skids" can include equipment that is small enough and light enough to be moved by one person, up to large or heavy units that can only be skidded with larger towing vehicles or lifted and moved with hoists or cranes. 1.3 This Standard applies to ac rated controls for which the load rating does not exceed 40 A per circuit at a maximum of 600 V. 1.4 SSCLS products may include receptacles of configuration 5-15R, 5-20R, and L5-20R, used as lighting load connection points, with access limited to qualified personnel only. 1.5 SSCLS products may include convenience receptacles, mechanical switches, dimming circuits, and other wiring devices on separate circuits. 1.6 SSCLS products may include NC (normally closed) or NO (normally open) contacts for the purpose of controlling other general-use loads rated inductive, resistive, and 2 hp or less. 1.7 SSCLS products may include a Class 2 power supply for the purpose of feeding power to analog or digital inputs, such as sensors. 1.8 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.9 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: