Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 165:17 (R2022)

CSA C22.2 NO. 165:17 (R2022) – Electric boilers

CDN $197.00

Electric boilers

SKU: 2425299 Categories: ,

Description

Preface This is the second edition of CSA C22.2 No. 165, Electric boilers , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This edition supersedes the first edition published in 1992. This Standard applies to stationary hot-water and steam boilers for residential, commercial, and industrial use that utilize metal-sheathed immersion-type heater elements and are intended for permanent connection to the source of supply. It does not apply to electrode-type boilers. The changes to this edition are as follows: a) reference documents updated; b) requirements modified for plated and unplated parts; c) references to transformer standards updated; d) references to IEC-based standards added; and e) Table 8 updated and reformatted. This Standard sets minimum requirements that are not intended to conflict with or supersede the requirements of CSA B51 or other applicable standards for boilers that fall under the provisions of the Boilers and Pressure Vessels Act of the provinces or territories of Canada. For general information on the standards of the Committee on Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2, No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Electric Boilers, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to stationary, permanently connected, hot-water and steam boilers for use with nominal system voltages of 600 V and less, for residential, commercial, and industrial use in nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I. 1.2 This Standard applies to boilers utilizing metal-sheathed-type heater elements. 1.3 This Standard does not apply to a) storage-type water heaters as covered in CAN/CSA-C22.2 No. 110; b) swimming pool and spa hot-water heaters; c) electrode-type boilers; d) industrial heating equipment covered in CSA C22.2 No. 88; or e) electric heating equipment for medical and dental use. 1.4 This Standard sets minimum requirements. It is not intended that the requirements of this Standard conflict with or supersede the requirements of CSA B51 or any other applicable standard for boilers that fall under the provisions of the Boilers and Pressure Vessels Act of the provinces or territories of Canada. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

53

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA C22.2 No. 165, Electric boilers , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This edition supersedes the first edition published in 1992. This Standard applies to stationary hot-water and steam boilers for residential, commercial, and industrial use that utilize metal-sheathed immersion-type heater elements and are intended for permanent connection to the source of supply. It does not apply to electrode-type boilers. The changes to this edition are as follows: a) reference documents updated; b) requirements modified for plated and unplated parts; c) references to transformer standards updated; d) references to IEC-based standards added; and e) Table 8 updated and reformatted. This Standard sets minimum requirements that are not intended to conflict with or supersede the requirements of CSA B51 or other applicable standards for boilers that fall under the provisions of the Boilers and Pressure Vessels Act of the provinces or territories of Canada. For general information on the standards of the Committee on Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2, No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Electric Boilers, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to stationary, permanently connected, hot-water and steam boilers for use with nominal system voltages of 600 V and less, for residential, commercial, and industrial use in nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I. 1.2 This Standard applies to boilers utilizing metal-sheathed-type heater elements. 1.3 This Standard does not apply to a) storage-type water heaters as covered in CAN/CSA-C22.2 No. 110; b) swimming pool and spa hot-water heaters; c) electrode-type boilers; d) industrial heating equipment covered in CSA C22.2 No. 88; or e) electric heating equipment for medical and dental use. 1.4 This Standard sets minimum requirements. It is not intended that the requirements of this Standard conflict with or supersede the requirements of CSA B51 or any other applicable standard for boilers that fall under the provisions of the Boilers and Pressure Vessels Act of the provinces or territories of Canada. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.