Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 159:18 (R2022)

CSA C22.2 NO. 159:18 (R2022) – Plugs, connectors, receptacles, and similar wiring devices for use in hazardous locations

CDN $362.00

Plugs, connectors, receptacles, and similar wiring devices for use in hazardous locations

SKU: 2424676 Categories: ,

Description

Preface This is the third edition of CSA C22.2 No. 159, Plugs, connectors, receptacles, and similar wiring devices for use in hazardous locations. It supersedes the previous editions published in 1987 and 1982 under the title Attachment plugs, receptacles, and similar wiring devices for use in hazardous locations. Changes to this edition include the a) addition of Division 2 and Class III; b) removal of requirements covered by other standards; and c) addition of Annex A to indicate how C22.2 No. 182.1 and C22.2 No. 182.3 are applied for the products covered by this Standard. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.  This Standard was prepared by the Integrated Committee on Hazardous Location Products under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety and has been formally approved by the technical committee This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers receptacles with attachment plugs; receptacles with attachment plugs interlocked with circuit breakers; receptacles with attachment plugs interlocked with switches; and cable and cord connectors, couplers, and flanged equipment power inlets and flanged equipment power outlets with ratings as specified in Clause 1.2 intended for connection to copper conductors only and for installation and use in the following hazardous locations in accordance with the Rules of Canadian Electrical Code, Part I and CSA M421: a) Class I, Division 1, Groups A, B, C, and D; b) Class I, Division 2, Groups A, B, C, and D; c) Class II, Groups F and G; and d) Class III. 1.2 This Standard covers a) Class I, Division 1 and Class II devices rated not more than 600 A or not more than 600 V ac or not more than 250 V dc; b) Class I, Division 2 devices rated not more than 1200 A and not more than 1000 V ac or not more than 1000 V dc; and c) equipment for gaseous mines rated not more than 1100 V ac. 1.3 This Standard does not cover plug and receptacle/connector combinations that do not incorporate either a delayed withdrawal, an interlock mechanism or other retaining device. Note: In this Standard, devices that are classified for Group G locations are acceptable for use in atmospheres containing coal or coke dust. 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

41

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the third edition of CSA C22.2 No. 159, Plugs, connectors, receptacles, and similar wiring devices for use in hazardous locations. It supersedes the previous editions published in 1987 and 1982 under the title Attachment plugs, receptacles, and similar wiring devices for use in hazardous locations. Changes to this edition include the a) addition of Division 2 and Class III; b) removal of requirements covered by other standards; and c) addition of Annex A to indicate how C22.2 No. 182.1 and C22.2 No. 182.3 are applied for the products covered by this Standard. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.  This Standard was prepared by the Integrated Committee on Hazardous Location Products under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety and has been formally approved by the technical committee This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers receptacles with attachment plugs; receptacles with attachment plugs interlocked with circuit breakers; receptacles with attachment plugs interlocked with switches; and cable and cord connectors, couplers, and flanged equipment power inlets and flanged equipment power outlets with ratings as specified in Clause 1.2 intended for connection to copper conductors only and for installation and use in the following hazardous locations in accordance with the Rules of Canadian Electrical Code, Part I and CSA M421: a) Class I, Division 1, Groups A, B, C, and D; b) Class I, Division 2, Groups A, B, C, and D; c) Class II, Groups F and G; and d) Class III. 1.2 This Standard covers a) Class I, Division 1 and Class II devices rated not more than 600 A or not more than 600 V ac or not more than 250 V dc; b) Class I, Division 2 devices rated not more than 1200 A and not more than 1000 V ac or not more than 1000 V dc; and c) equipment for gaseous mines rated not more than 1100 V ac. 1.3 This Standard does not cover plug and receptacle/connector combinations that do not incorporate either a delayed withdrawal, an interlock mechanism or other retaining device. Note: In this Standard, devices that are classified for Group G locations are acceptable for use in atmospheres containing coal or coke dust. 1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: