
CSA C22.2 NO. 0.22:11 (R2026)
CSA C22.2 NO. 0.22:11 (R2026) – Evaluation methods for arc resistance ratings of enclosed electrical equipment
CDN $320.00
Evaluation methods for arc resistance ratings of enclosed electrical equipment
Description
Preface This is the first edition of CSA C22.2 No. 0.22, Evaluation methods for arc resistance ratings of enclosed electrical equipment, one of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard establishes methods by which metal-enclosed equipment can be tested for resistance to the effects of arcing resulting from an internal fault. 1.2 This Standard applies only to indoor and outdoor equipment that uses air as the primary insulating medium and that is rated up to 46 kV ac. Note: Building size and construction are factors to be considered in indoor applications. These factors are not addressed in this Standard. 1.3 The tests and assessments described in this Standard are applicable only to arcing faults occurring entirely in air within the enclosure when all doors and covers are properly secured. 1.4 This Standard does not apply to arcing faults that occur within a component of the assembly, such as instrument transformers, sealed interrupting devices, or fuses. 1.5 Metal-enclosed switchgear designs that meet the requirements of this Standard are referred to as arc-resistant switchgear. Motor control designs that meet the requirements of this Standard are referred to as arc-resistant motor control. Note: Annex C provides additional information on the consequences of internal arc faults, equipment qualified to this Standard, relevance of tests, and the application of this Standard. 1.6 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. 1.7 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
52
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of CSA C22.2 No. 0.22, Evaluation methods for arc resistance ratings of enclosed electrical equipment, one of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard establishes methods by which metal-enclosed equipment can be tested for resistance to the effects of arcing resulting from an internal fault. 1.2 This Standard applies only to indoor and outdoor equipment that uses air as the primary insulating medium and that is rated up to 46 kV ac. Note: Building size and construction are factors to be considered in indoor applications. These factors are not addressed in this Standard. 1.3 The tests and assessments described in this Standard are applicable only to arcing faults occurring entirely in air within the enclosure when all doors and covers are properly secured. 1.4 This Standard does not apply to arcing faults that occur within a component of the assembly, such as instrument transformers, sealed interrupting devices, or fuses. 1.5 Metal-enclosed switchgear designs that meet the requirements of this Standard are referred to as arc-resistant switchgear. Motor control designs that meet the requirements of this Standard are referred to as arc-resistant motor control. Note: Annex C provides additional information on the consequences of internal arc faults, equipment qualified to this Standard, relevance of tests, and the application of this Standard. 1.6 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. 1.7 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart -

CSA SPE-1000:25 – Model Code for the field evaluation of electrical equipment
CDN $378.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E60825-1:15 (R2025) – Safety of laser products — Part 1: Equipment classification and requirements (Adopted IEC 60825-1:2014, third edition, 2014-05, with Canadian deviations) | Sécurité des appareils à laser — Partie 1 : Classification des matériels et exigences (norme IEC 60825-1:2014 adoptée, troisième édition, 2014-05, avec exigences propres au Canada)
CDN $488.00 Add to cart







