Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA B140.9.4:10 (R2024)

CSA B140.9.4:10 (R2024) – Portable, pressurized-type, liquid-petroleum-fuelled lamps and lanterns

CDN $142.00

Portable, pressurized-type, liquid-petroleum-fuelled lamps and lanterns

SKU: 2420431 Categories: ,

Description

Preface This is the second edition of CSA B140.9.4, Portable, pressurized-type, liquid-petroleum-fuelled lamps and lanterns . It supersedes the previous edition, published in 1979. It is the third in a series of Standards covering minimum requirements for safe operation, acceptable performance, marking, and testing of portable, liquid-fuel-burning appliances. The other Standards in the series are (a) CSA B140.9.1, Portable liquid fuelled catalytic appliances; and (b) CSA B140.9.2, Portable, pressurized-type, liquid-petroleum-fuelled camp stoves. Safe and satisfactory use of portable, liquid-fuelled appliances depends in part on correct operation and the burning of appropriate fuel. Although these appliances do not require installation and are generally self-contained, the intent and the definitions of the latest edition of CSA B139, Installation code for oil-burning equipment, should be applied to the use of this equipment. This Standard has been revised to reflect SI units as the primary measurement system and to update the instructions and marking requirements. This Standard was prepared by the Technical Committee on Oil Burning Appliance Standards, under the jurisdiction of the Strategic Steering Committee on Fuel Burning Equipment, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to portable, pressurized-type, liquid-petroleum-fuelled lamps and lanterns with one or more burners. Note: The term “device” as used in this Standard refers to both lamps and lanterns as defined in Clause 3. The term “lamp” or “lantern” is used where specific reference is intended. 1.2 This Standard applies to devices intended for use outdoors only. 1.3 This Standard may be applied to devices using alcohol-type fuel with a pressurized fuel system. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

31

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA B140.9.4, Portable, pressurized-type, liquid-petroleum-fuelled lamps and lanterns . It supersedes the previous edition, published in 1979. It is the third in a series of Standards covering minimum requirements for safe operation, acceptable performance, marking, and testing of portable, liquid-fuel-burning appliances. The other Standards in the series are (a) CSA B140.9.1, Portable liquid fuelled catalytic appliances; and (b) CSA B140.9.2, Portable, pressurized-type, liquid-petroleum-fuelled camp stoves. Safe and satisfactory use of portable, liquid-fuelled appliances depends in part on correct operation and the burning of appropriate fuel. Although these appliances do not require installation and are generally self-contained, the intent and the definitions of the latest edition of CSA B139, Installation code for oil-burning equipment, should be applied to the use of this equipment. This Standard has been revised to reflect SI units as the primary measurement system and to update the instructions and marking requirements. This Standard was prepared by the Technical Committee on Oil Burning Appliance Standards, under the jurisdiction of the Strategic Steering Committee on Fuel Burning Equipment, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to portable, pressurized-type, liquid-petroleum-fuelled lamps and lanterns with one or more burners. Note: The term "device" as used in this Standard refers to both lamps and lanterns as defined in Clause 3. The term "lamp" or "lantern" is used where specific reference is intended. 1.2 This Standard applies to devices intended for use outdoors only. 1.3 This Standard may be applied to devices using alcohol-type fuel with a pressurized fuel system. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.5 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: