Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA B127.3:21

CSA B127.3:21 – Fibrocement drain, waste, and vent pipe and pipe fittings

CDN $247.00

Fibrocement drain, waste, and vent pipe and pipe fittings

Description

Preface This is the second edition of CSA B127.3, Fibrocement drain, waste, and vent pipe and pipe fittings . It supersedes the previous edition published in 2018. The major changes in this new edition are the following: a) revision to dimensioning procedure; b) test sample clarification for cement quality test; c) removal of joint tightness test; d) replacement of bending test, lap shear test, and bend back test with glue adhesion strength test for fabricated fittings; e) revision to conditioning requirements; f) revisions to straightness, crushing, cement quality, and hydrostatic strength test methods; g) additional sizes and revisions to the pipe dimensions; h) additional sizes and revisions to moulded fitting minimum radius; i) addition of general installation and additional information added for above-ground installation to Annex A; and j) clarification of processing additives in Annex B. This Standard was prepared by the Technical Committee on Asbestos Cement and Fibrocement Drain, Waste, and Vent Pipe and Pipe Fittings, under the jurisdiction of the Strategic Steering Committee on Construction and Civil Infrastructure, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers fibrocement Type 1 (Class 3000) and Type 2 (Class 4000) pipe and pipe fittings for installation in storm and sanitary drainage systems for drain, waste, and vent (DWV) inside and outside of buildings, above and below grade. 1.2 This Standard includes specifications for material, dimensions, crushing strength, chemical resistance, and joint tightness. Methods of marking to indicate compliance with these requirements are included. Recommended installation practice is given in Annex A. Suitability of material composition is given in Annex B. 1.3 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. All pipe sizes are shown as nominal pipe sizes (NPS). 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

41

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA B127.3, Fibrocement drain, waste, and vent pipe and pipe fittings . It supersedes the previous edition published in 2018. The major changes in this new edition are the following: a) revision to dimensioning procedure; b) test sample clarification for cement quality test; c) removal of joint tightness test; d) replacement of bending test, lap shear test, and bend back test with glue adhesion strength test for fabricated fittings; e) revision to conditioning requirements; f) revisions to straightness, crushing, cement quality, and hydrostatic strength test methods; g) additional sizes and revisions to the pipe dimensions; h) additional sizes and revisions to moulded fitting minimum radius; i) addition of general installation and additional information added for above-ground installation to Annex A; and j) clarification of processing additives in Annex B. This Standard was prepared by the Technical Committee on Asbestos Cement and Fibrocement Drain, Waste, and Vent Pipe and Pipe Fittings, under the jurisdiction of the Strategic Steering Committee on Construction and Civil Infrastructure, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers fibrocement Type 1 (Class 3000) and Type 2 (Class 4000) pipe and pipe fittings for installation in storm and sanitary drainage systems for drain, waste, and vent (DWV) inside and outside of buildings, above and below grade. 1.2 This Standard includes specifications for material, dimensions, crushing strength, chemical resistance, and joint tightness. Methods of marking to indicate compliance with these requirements are included. Recommended installation practice is given in Annex A. Suitability of material composition is given in Annex B. 1.3 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. All pipe sizes are shown as nominal pipe sizes (NPS). 1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: