Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

ANSI Z21.50:19 (R2024)/CSA 2.22:19 (R2024)

ANSI Z21.50:19 (R2024)/CSA 2.22:19 (R2024) – Vented decorative gas appliances

CDN $1,319.00

Vented decorative gas appliances

SKU: 2425435 Categories: ,

Description

Preface This is the ninth edition of ANSI Z21.50 • CSA 2.22, Vented decorative gas appliances. It supersedes the previous editions published in 2016, 2014, 2012, 2007, 2003, 2000, 1998, and 1996. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Z21/CSA Joint Technical Subcommittee on Vented Gas-Fired Warm Air Heaters, under the jurisdiction of the Z21/83 Technical Committee on Performance and Installation of Gas-Burning Appliances and Related Accessories and the Strategic Steering Committee on Fuels and Appliances. It has been formally approved by the Z21/83 Technical Committee, the Technical Committee on Gas Appliances and Related Accessories, and the Interprovincial Gas Advisory Council. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 This Standard applies to newly produced vented decorative gas appliances (see Clause 3, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials and having input ratings up to and including 400,000 Btu/hr (117 228 W). These appliances are for: a) use with natural gas; b) use with propane; c) direct vent gas appliances for manufactured home (USA only) or mobile home OEM installation or aftermarket installation convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other (see Clauses 4.1.22 and 4.1.23); d) direct vent gas appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only (see Clause 4.1.23); and e) direct vent gas appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only (see Clause 4.1.22). The construction of vented decorative gas appliances for use with the above-mentioned gases is covered under Clause 4, Construction. The performance of vented decorative gas appliances for use with the above-mentioned gases is covered under Clause 5, Performance. 1.2 These appliances are not: a) for use with a thermostat; b) a source of heat; and c) for use with solid fuels. 1.3 Annex I, Automatic intermittent pilot ignition or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on- demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance. 1.4 If a value for measurement given in this Standard is followed by an equivalent value in other units, the first stated value is the specification. 1.5 Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. It is the responsibility of the user of this Standard to determine which referenced standard applies based on the requirements of the Authority Having Jurisdiction (AHJ) for the location of installation. 1.6 This Standard also applies to appliances with draft hoods that are factory equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices. 1.7 All references to “psi” throughout this Standard are to be considered gauge pressure unless otherwise specified. 1.8 Special construction provisions applicable to vented decorative gas appliances designed for use with an optional design-certified conversion kit are outlined under Annex A, Provisions for listed gas appliance conversion kits (optional). 1.9 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

247

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the ninth edition of ANSI Z21.50 • CSA 2.22, Vented decorative gas appliances. It supersedes the previous editions published in 2016, 2014, 2012, 2007, 2003, 2000, 1998, and 1996. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Z21/CSA Joint Technical Subcommittee on Vented Gas-Fired Warm Air Heaters, under the jurisdiction of the Z21/83 Technical Committee on Performance and Installation of Gas-Burning Appliances and Related Accessories and the Strategic Steering Committee on Fuels and Appliances. It has been formally approved by the Z21/83 Technical Committee, the Technical Committee on Gas Appliances and Related Accessories, and the Interprovincial Gas Advisory Council. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 This Standard applies to newly produced vented decorative gas appliances (see Clause 3, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials and having input ratings up to and including 400,000 Btu/hr (117 228 W). These appliances are for: a) use with natural gas; b) use with propane; c) direct vent gas appliances for manufactured home (USA only) or mobile home OEM installation or aftermarket installation convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other (see Clauses 4.1.22 and 4.1.23); d) direct vent gas appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only (see Clause 4.1.23); and e) direct vent gas appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only (see Clause 4.1.22). The construction of vented decorative gas appliances for use with the above-mentioned gases is covered under Clause 4, Construction. The performance of vented decorative gas appliances for use with the above-mentioned gases is covered under Clause 5, Performance. 1.2 These appliances are not: a) for use with a thermostat; b) a source of heat; and c) for use with solid fuels. 1.3 Annex I, Automatic intermittent pilot ignition or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on- demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance. 1.4 If a value for measurement given in this Standard is followed by an equivalent value in other units, the first stated value is the specification. 1.5 Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. It is the responsibility of the user of this Standard to determine which referenced standard applies based on the requirements of the Authority Having Jurisdiction (AHJ) for the location of installation. 1.6 This Standard also applies to appliances with draft hoods that are factory equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices. 1.7 All references to "psi" throughout this Standard are to be considered gauge pressure unless otherwise specified. 1.8 Special construction provisions applicable to vented decorative gas appliances designed for use with an optional design-certified conversion kit are outlined under Annex A, Provisions for listed gas appliance conversion kits (optional). 1.9 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: