Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA A500:16 (R2021)

CSA A500:16 (R2021) – Building guards

CDN $276.00

Building guards

Description

Preface This is the first edition of CSA A500, Building guards . This Standard was prepared in response to requests from stakeholders who saw the need for a standard for materials, design, construction, testing, and performance of building guards. The Standard was developed through the collaboration of designers, engineers, fabricators, suppliers, building owners, property developers, regulators, and other technical specialists. Special recognition is given to the members of the Writers Working Group for developing content for this Standard. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Concord Adex, Daniels Group, Grappe Industrielle d’Aluminium du Québec (GIAQ), Ontario Ministry of Municipal Affairs and Housing, RESCON, Royal Guard, State Window Corporation, Toro Aluminum Railings, and Tridel-Deltera. Introduction 0.1 General This Standard was developed in response to a request from stakeholders who saw the need for a standard for materials, design, construction, testing, and performance of building guards. 0.2 Intent The intent of this Standard is to specify minimum requirements for the materials, design, construction, testing, and performance of building guards and to provide guidance on assessing guards to maintain ongoing minimum performance levels. This Standard is intended to be a) adopted by building code regulations in provinces and territories across Canada; b) reviewed and updated from time to time to reflect the current state of knowledge of building guards; and c) used in its entirety. Scope 1.1 General This Standard specifies requirements for the materials, design, construction, testing, and performance of building guards. This Standard applies to building guards required as protective barriers to prevent accidental falls from one level to another. Notes: 1) This includes walls acting as guards. 2) Guards can be with or without openings, around openings in floors, or at the open sides of stairs, landings, balconies, mezzanines, galleries, raised walkways, or other locations. 1.2 Exclusions This Standard does not apply to a) temporary guards regulated elsewhere by applicable health and safety requirements; b) guards for resisting impact from vehicles; c) guards used in Group F (industrial occupancy) buildings as set out by the National Building Code of Canada (NBC); and d) guards used in Group A (assembly occupancy) buildings that are permitted to be designed to other requirements as set out by the National Building Code of Canada (NBC), such as in places of assembly with fixed seats or bleacher seats. 1.3 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

118

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA A500, Building guards . This Standard was prepared in response to requests from stakeholders who saw the need for a standard for materials, design, construction, testing, and performance of building guards. The Standard was developed through the collaboration of designers, engineers, fabricators, suppliers, building owners, property developers, regulators, and other technical specialists. Special recognition is given to the members of the Writers Working Group for developing content for this Standard. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Concord Adex, Daniels Group, Grappe Industrielle d’Aluminium du Québec (GIAQ), Ontario Ministry of Municipal Affairs and Housing, RESCON, Royal Guard, State Window Corporation, Toro Aluminum Railings, and Tridel-Deltera. Introduction 0.1 General This Standard was developed in response to a request from stakeholders who saw the need for a standard for materials, design, construction, testing, and performance of building guards. 0.2 Intent The intent of this Standard is to specify minimum requirements for the materials, design, construction, testing, and performance of building guards and to provide guidance on assessing guards to maintain ongoing minimum performance levels. This Standard is intended to be a) adopted by building code regulations in provinces and territories across Canada; b) reviewed and updated from time to time to reflect the current state of knowledge of building guards; and c) used in its entirety. Scope 1.1 General This Standard specifies requirements for the materials, design, construction, testing, and performance of building guards. This Standard applies to building guards required as protective barriers to prevent accidental falls from one level to another. Notes: 1) This includes walls acting as guards. 2) Guards can be with or without openings, around openings in floors, or at the open sides of stairs, landings, balconies, mezzanines, galleries, raised walkways, or other locations. 1.2 Exclusions This Standard does not apply to a) temporary guards regulated elsewhere by applicable health and safety requirements; b) guards for resisting impact from vehicles; c) guards used in Group F (industrial occupancy) buildings as set out by the National Building Code of Canada (NBC); and d) guards used in Group A (assembly occupancy) buildings that are permitted to be designed to other requirements as set out by the National Building Code of Canada (NBC), such as in places of assembly with fixed seats or bleacher seats. 1.3 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: