Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

A123.3-05 (R2020)

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

CDN $150.00

Asphalt saturated organic roofing felt

Description

Preface This is the third edition of CSA A123.3, Asphalt saturated organic roofing felt . It supersedes the second edition, published in 1998, and the first edition, Asphalt or Tar Saturated Organic Roofing Felt, published in 1979. It is one of a series of CSA Standards on bituminous roofing materials (CSA A123.1 to A123.5). The CSA A123 series of Standards are written in SI (metric) units, which are in conformance with CAN/CSA-Z234.1. Scope 1.1 This Standard covers asphalt saturated organic roofing felt, with perforations, to be used with roofing asphalts conforming to CSA A123.4 in the construction of built-up roofing membranes, without perforations, applied as an underlayment beneath asphalt shingles, woods shakes and shingles, tiles, and other roof coverings. 1.2 The following types of roofing felts are addressed by this Standard: (a) Type 1 – perforated roofing felt that is used in the construction of built-up roofing membranes. It is commonly referred to as No. 15 Felt Perforated. (b) Type 2 – plain, non-perforated roofing felt used as an underlayment beneath asphalt shingles, wood shakes and shingles, tiles, and other steep slope roof coverings. It is commonly referred to as No. 15 Plain Felt. (c) Type 3 – plain, non-perforated roofing felt used as an underlayment beneath asphalt shingles, wood shakes and shingles, tiles, and other steep slope roof coverings. It is commonly referred to as No. 30 Plain Felt. 1.3 The values given in SI (metric) units are the standard. The values given in parentheses are for information only. 1.4 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

Not found

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the third edition of CSA A123.3, Asphalt saturated organic roofing felt . It supersedes the second edition, published in 1998, and the first edition, Asphalt or Tar Saturated Organic Roofing Felt, published in 1979. It is one of a series of CSA Standards on bituminous roofing materials (CSA A123.1 to A123.5). The CSA A123 series of Standards are written in SI (metric) units, which are in conformance with CAN/CSA-Z234.1. Scope 1.1 This Standard covers asphalt saturated organic roofing felt, with perforations, to be used with roofing asphalts conforming to CSA A123.4 in the construction of built-up roofing membranes, without perforations, applied as an underlayment beneath asphalt shingles, woods shakes and shingles, tiles, and other roof coverings. 1.2 The following types of roofing felts are addressed by this Standard: (a) Type 1 - perforated roofing felt that is used in the construction of built-up roofing membranes. It is commonly referred to as No. 15 Felt Perforated. (b) Type 2 - plain, non-perforated roofing felt used as an underlayment beneath asphalt shingles, wood shakes and shingles, tiles, and other steep slope roof coverings. It is commonly referred to as No. 15 Plain Felt. (c) Type 3 - plain, non-perforated roofing felt used as an underlayment beneath asphalt shingles, wood shakes and shingles, tiles, and other steep slope roof coverings. It is commonly referred to as No. 30 Plain Felt. 1.3 The values given in SI (metric) units are the standard. The values given in parentheses are for information only. 1.4 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: