ISO 10136:1993

ISO 10136:1993 Glass and glassware – Analysis of extract solutions – Part 2: Determination of sodium oxide and potassium oxide by flame spectrometric methods

CDN $85.00

SKU: 4f2d997482c9 Categories: ,

Description

The principle of the method specified is spraying the extract solution into the flame of the burner of an emission or absorption spectrometer, if necessary with the addition of a spectrochemical buffer solution, or into the flame of a filter flame spectrometer without this addition. For FES and FAAS, the lines at 589,0 nm and 766,5 nm, respectively, are used and compared with the measurements of reference solutions, for a flame filter spectrometer, the specific filters are used. Measures the concentrations of sodium and potassium, expressed as their oxides Na2O and K2O. Applies to the analysis of extract solutions obtained from any kind of glass or glassware.

Edition

1

Published Date

1993-07-01

Status

PUBLISHED

Pages

6

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

The principle of the method specified is spraying the extract solution into the flame of the burner of an emission or absorption spectrometer, if necessary with the addition of a spectrochemical buffer solution, or into the flame of a filter flame spectrometer without this addition. For FES and FAAS, the lines at 589,0 nm and 766,5 nm, respectively, are used and compared with the measurements of reference solutions, for a flame filter spectrometer, the specific filters are used. Measures the concentrations of sodium and potassium, expressed as their oxides Na2O and K2O. Applies to the analysis of extract solutions obtained from any kind of glass or glassware.