ISO 10211:2017

ISO 10211:2017 Thermal bridges in building construction – Heat flows and surface temperatures – Detailed calculations

CDN $397.00

SKU: c8b92ebcdb85 Categories: ,

Description

ISO 10211:2017 sets out the specifications for a three-dimensional and a two-dimensional geometrical model of a thermal bridge for the numerical calculation of

– heat flows, in order to assess the overall heat loss from a building or part of it, and

– minimum surface temperatures, in order to assess the risk of surface condensation.

These specifications include the geometrical boundaries and subdivisions of the model, the thermal boundary conditions, and the thermal values and relationships to be used.

ISO 10211:2017 is based upon the following assumptions:

– all physical properties are independent of temperature;

– there are no heat sources within the building element.

ISO 10211:2017 can also be used for the derivation of linear and point thermal transmittances and of surface temperature factors.

NOTE Table 1 in the Introduction shows the relative position of ISO 10211:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

Edition

2

Published Date

2017-06-21

Status

PUBLISHED

Pages

55

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 10211:2017 sets out the specifications for a three-dimensional and a two-dimensional geometrical model of a thermal bridge for the numerical calculation of

- heat flows, in order to assess the overall heat loss from a building or part of it, and

- minimum surface temperatures, in order to assess the risk of surface condensation.

These specifications include the geometrical boundaries and subdivisions of the model, the thermal boundary conditions, and the thermal values and relationships to be used.

ISO 10211:2017 is based upon the following assumptions:

- all physical properties are independent of temperature;

- there are no heat sources within the building element.