Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 10218:2025

ISO 10218:2025 Robotics – Safety requirements – Part 1: Industrial robots

CDN $390.00

SKU: 65577d4f39c9 Categories: ,

Description

This document specifies requirements for the inherently safe design, risk reduction measures and information for use of robots for an industrial environment.

This document addresses the robot as an incomplete machine.

This document is not applicable to the following uses and products:

-     underwater;

-     law enforcement;

-     military (defence);

-     airborne and space robots, including outer space;

-     medical robots;

-     healthcare robots;

-     prosthetics and other aids for the physically impaired;

-     service robots, which provide a service to a person and as such where the public can have access;

-     consumer products, as this is household use to which the public can have access;

-     lifting or transporting people.

NOTE 1        Requirements for robot integration and robot applications are covered in ISO 10218-2:2025.

NOTE 2        Additional hazards can be created by robot applications (e.g. welding, laser cutting, machining). These hazards are addressed during robot application design. See ISO 10218-2:2025.

This document deals with the significant hazards, hazardous situations or hazardous events when used as intended and under specified conditions of misuse which are reasonably foreseeable by the manufacturer.

This document does not cover the hazards related to:

-     severe conditions (e.g. extreme climates, freezer use, strong magnetic fields) outside of manufacturer’s specifications;

-     underground use;

-     use that has hygienic requirements;

-     use in nuclear environments;

-     use in potentially explosive environments;

-     mobility when robots or manipulators are fixed to or part of driverless industrial trucks;

-     mobility when robots or manipulators are fixed to or part of mobile platforms;

-     use in environments with ionizing and non-ionizing radiation levels;

-     hazardous ionizing and non-ionizing radiation;

-     handling loads the nature of which can lead to dangerous situations (e.g. molten metals, acids/bases, radiating materials);

-     handling or lifting or transporting people;

-     when the public, all ages or non-working adults have access (e.g. service robots, consumer products).

Noise emission is generally not considered a significant hazard of the robot alone, and consequently noise is excluded from the scope of this document.

This document is not applicable to robots that are manufactured before the date of its publication.

Edition

3

Published Date

2025-02-05

Status

PUBLISHED

Pages

95

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies requirements for the inherently safe design, risk reduction measures and information for use of robots for an industrial environment.

This document addresses the robot as an incomplete machine.

This document is not applicable to the following uses and products:

-     underwater;

-     law enforcement;

-     military (defence);

-     airborne and space robots, including outer space;

-     medical robots;

-     healthcare robots;

-     prosthetics and other aids for the physically impaired;

-     service robots, which provide a service to a person and as such where the public can have access;

-     consumer products, as this is household use to which the public can have access;

-     lifting or transporting people.

NOTE 1        Requirements for robot integration and robot applications are covered in ISO 10218-2:2025.

NOTE 2        Additional hazards can be created by robot applications (e.g. welding, laser cutting, machining). These hazards are addressed during robot application design. See ISO 10218-2:2025.

This document deals with the significant hazards, hazardous situations or hazardous events when used as intended and under specified conditions of misuse which are reasonably foreseeable by the manufacturer.

This document does not cover the hazards related to:

-     severe conditions (e.g. extreme climates, freezer use, strong magnetic fields) outside of manufacturer’s specifications;

-     underground use;

-     use that has hygienic requirements;

-     use in nuclear environments;

-     use in potentially explosive environments;

-     mobility when robots or manipulators are fixed to or part of driverless industrial trucks;

-     mobility when robots or manipulators are fixed to or part of mobile platforms;

-     use in environments with ionizing and non-ionizing radiation levels;

-     hazardous ionizing and non-ionizing radiation;

-     handling loads the nature of which can lead to dangerous situations (e.g. molten metals, acids/bases, radiating materials);

-     handling or lifting or transporting people;

-     when the public, all ages or non-working adults have access (e.g. service robots, consumer products).

Noise emission is generally not considered a significant hazard of the robot alone, and consequently noise is excluded from the scope of this document.

This document is not applicable to robots that are manufactured before the date of its publication.

Previous Editions

Can’t find what you are looking for?

Please contact us at: