Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

TEMA 2026 Edition – Online Subscription Only

$

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 15SIH, 2nd Edition: Installation and Handling of Spoolable Reinforced Plastic Line Pipe

$

158

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 754, 4th Edition: Process Safety Performance Indicators for the Refining and Petrochemical Industries

$

393

BUY NOW

Placeholder headline

This is just a placeholder headline

ASME B31.1-2020: Power Piping

$

668

BUY NOW

Placeholder headline

This is just a placeholder headline

ASME B31.1-2022: Power Piping

$

668

BUY NOW

ISO 10993:2017

ISO 10993:2017 Biological evaluation of medical devices – Part 22: Guidance on nanomaterials

CDN $393.00

SKU: 5f18f7295896 Category:

Description

ISO/TR 10993-22:2017 describes considerations for the biological evaluation of medical devices that are composed of or contain nanomaterials. In addition, this guidance can also be used for the evaluation of nano-objects generated as products of degradation, wear, or from mechanical treatment processes (e.g. in situ grinding, polishing of medical devices) from (components of) medical devices that are manufactured not using nanomaterials.

ISO/TR 10993-22:2017 includes considerations on the:

– characterization of nanomaterials;

– sample preparation for testing of nanomaterials;

– release of nano-objects from medical devices;

– toxicokinetics of nano-objects;

– biological evaluation of nanomaterials;

– presentation of results;

– risk assessment of nanomaterials in the context of medical device evaluation;

– biological evaluation report;

– nanostructures on the surface of a medical device, intentionally generated during the engineering, manufacturing or processing of a medical device.

The following are excluded from this document:

– natural and biological nanomaterials, as long as they have not been engineered, manufactured or processed for use in a medical device;

– intrinsic nanostructures in a bulk material;

– nanostructures on the surface of a medical device, generated as an unintentional by-product during the engineering, manufacturing or processing of a medical device.

NOTE Examples of unintentional nanostructures on the surface of a medical device are extrusion draw lines and machining/tool marks.

ISO/TR 10993-22:2017 is intended to provide a general framework and highlights important aspects which need to be considered when assessing the safety of medical devices composed of, containing and/or generating nano-objects. Additionally, the document identifies several common pitfalls and obstacles which have been identified when testing nanomaterials compared to bulk materials or small molecule chemical species. As a technical report (TR), this document represents the current technical knowledge related to nanomaterials. No detailed testing protocols are outlined or provided. This document can serve as a basis for future documents containing detailed protocols with a focus on nanomaterial testing.

Edition

1

Published Date

2017-07-14

Status

PUBLISHED

Pages

61

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO/TR 10993-22:2017 describes considerations for the biological evaluation of medical devices that are composed of or contain nanomaterials. In addition, this guidance can also be used for the evaluation of nano-objects generated as products of degradation, wear, or from mechanical treatment processes (e.g. in situ grinding, polishing of medical devices) from (components of) medical devices that are manufactured not using nanomaterials.

ISO/TR 10993-22:2017 includes considerations on the:

- characterization of nanomaterials;

- sample preparation for testing of nanomaterials;

- release of nano-objects from medical devices;

- toxicokinetics of nano-objects;

- biological evaluation of nanomaterials;

- presentation of results;

- risk assessment of nanomaterials in the context of medical device evaluation;

- biological evaluation report;

- nanostructures on the surface of a medical device, intentionally generated during the engineering, manufacturing or processing of a medical device.

The following are excluded from this document:

- natural and biological nanomaterials, as long as they have not been engineered, manufactured or processed for use in a medical device;

- intrinsic nanostructures in a bulk material;

- nanostructures on the surface of a medical device, generated as an unintentional by-product during the engineering, manufacturing or processing of a medical device.

NOTE Examples of unintentional nanostructures on the surface of a medical device are extrusion draw lines and machining/tool marks.

ISO/TR 10993-22:2017 is intended to provide a general framework and highlights important aspects which need to be considered when assessing the safety of medical devices composed of, containing and/or generating nano-objects. Additionally, the document identifies several common pitfalls and obstacles which have been identified when testing nanomaterials compared to bulk materials or small molecule chemical species. As a technical report (TR), this document represents the current technical knowledge related to nanomaterials. No detailed testing protocols are outlined or provided. This document can serve as a basis for future documents containing detailed protocols with a focus on nanomaterial testing.

Previous Editions

Can’t find what you are looking for?

Please contact us at: