ISO 11222:2002
ISO 11222:2002 Air quality – Determination of the uncertainty of the time average of air quality measurements
CDN $233.00
Description
ISO 11222:2002 provides a method for the quantification of the uncertainty of a time average of a set of air quality data obtained at a specified location over a defined averaging time period. The method is applicable to air quality data obtained by continuous or intermittent monitoring by means of a specified measuring system. The uncertainty of the time average depends on both the uncertainty of the measurement results and the uncertainty due to incomplete time coverage of the data set.
ISO 11222:2002 is only applicable if
- the set of air quality data used to calculate the time average is representative of the temporal structure of the measurand over the defined time period,
- appropriate information on the uncertainty of the measurement results is available, and
- the measurement results have all been obtained at the same location.
ISO 11222:2002 implements recommendations of the Guide to the Expression of Uncertainty in Measurement (GUM).
Edition
1
Published Date
2002-07-04
Status
PUBLISHED
Pages
20
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 11222:2002 provides a method for the quantification of the uncertainty of a time average of a set of air quality data obtained at a specified location over a defined averaging time period. The method is applicable to air quality data obtained by continuous or intermittent monitoring by means of a specified measuring system. The uncertainty of the time average depends on both the uncertainty of the measurement results and the uncertainty due to incomplete time coverage of the data set.
ISO 11222:2002 is only applicable if
- the set of air quality data used to calculate the time average is representative of the temporal structure of the measurand over the defined time period,
- appropriate information on the uncertainty of the measurement results is available, and
- the measurement results have all been obtained at the same location.
ISO 11222:2002 implements recommendations of the Guide to the Expression of Uncertainty in Measurement (GUM).
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 14956:2002 Air quality – Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
CDN $233.00 Add to cart -

ISO 4225:2020 Air quality – General aspects – Vocabulary
CDN $76.00 Add to cart -

ISO 11665:2018 Measurement of radioactivity in the environment – Air: radon-222 – Part 12: Determination of the diffusion coefficient in waterproof materials: membrane one-side activity concentration measurement method
CDN $273.00 Add to cart -

ISO 11665:2016 Measurement of radioactivity in the environment – Air: radon-222 – Part 11: Test method for soil gas with sampling at depth
CDN $233.00 Add to cart