
ISO 1179:2013
ISO 1179:2013 Connections for general use and fluid power – Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing – Part 1: Threaded ports
CDN $76.00
Description
ISO 1179-1:2013 specifies dimensions for ports with ISO 228‚Äë1 threads for use with non-adjustable stud ends described in ISO 1179‚Äë2, ISO 1179‚Äë3 and ISO 1179‚Äë4 and with adjustable stud ends described in ISO 1179‚Äë3.
Ports in accordance with ISO 1179-1:2013 are applicable for use with ISO 1179‚Äë2 heavy-duty (S series) stud ends with type E sealing at working pressures up to 63 MPa (630 bar) and light-duty (L series) stud ends at working pressures up to 25 MPa (250 bar), ISO 1179‚Äë3 light-duty (L series) stud ends with type G sealing at working pressures up to 31,5 MPa (315 bar), and with ISO 1179‚Äë3 light-duty (L series) adjustable stud ends with type H sealing at working pressures up to 20 MPa (200 bar), and ISO 1179‚Äë4 stud ends with type B sealing at working pressures up to 40 MPa (400 bar) for the S series, up to 25 MPa (250 bar) for the L series, and up to 10 MPa (100 bar) for the LL series, except for the G2 size port, which in hydraulic fluid power systems is used mainly with accumulators and for which ISO 1179‚Äë3 and ISO 1179‚Äë4 do not specify stud ends. The permissible working pressure depends upon size, materials, design, working conditions, application, etc.
Edition
2
Published Date
2013-10-22
Status
PUBLISHED
Pages
6
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 1179-1:2013 specifies dimensions for ports with ISO 228‚Äë1 threads for use with non-adjustable stud ends described in ISO 1179‚Äë2, ISO 1179‚Äë3 and ISO 1179‚Äë4 and with adjustable stud ends described in ISO 1179‚Äë3.
Ports in accordance with ISO 1179-1:2013 are applicable for use with ISO 1179‚Äë2 heavy-duty (S series) stud ends with type E sealing at working pressures up to 63 MPa (630 bar) and light-duty (L series) stud ends at working pressures up to 25 MPa (250 bar), ISO 1179‚Äë3 light-duty (L series) stud ends with type G sealing at working pressures up to 31,5 MPa (315 bar), and with ISO 1179‚Äë3 light-duty (L series) adjustable stud ends with type H sealing at working pressures up to 20 MPa (200 bar), and ISO 1179‚Äë4 stud ends with type B sealing at working pressures up to 40 MPa (400 bar) for the S series, up to 25 MPa (250 bar) for the L series, and up to 10 MPa (100 bar) for the LL series, except for the G2 size port, which in hydraulic fluid power systems is used mainly with accumulators and for which ISO 1179‚Äë3 and ISO 1179‚Äë4 do not specify stud ends. The permissible working pressure depends upon size, materials, design, working conditions, application, etc.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 612:1978 Road vehicles – Dimensions of motor vehicles and towed vehicles – Terms and definitions
CDN $173.00 Add to cart -

ISO 80004:2020 Nanotechnologies – Vocabulary – Part 3: Carbon nano-objects
CDN $76.00 Add to cart -

ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
CDN $273.00 Add to cart -

ISO 5078:2025 Management of terminology resources – Terminology extraction
CDN $233.00 Add to cart







