
ISO 11843:2008
ISO 11843:2008 Capability of detection – Part 5: Methodology in the linear and non-linear calibration cases
CDN $195.00
Description
ISO 11843-5:2008 is concerned with calibration functions that are either linear or non-linear. It specifies basic methods to construct a precision profile for the response variable, namely a description of the standard deviation or coefficient of variation of the response variable as a function of the net state variable, transform this precision profile into a precision profile for the net state variable in conjunction with the calibration function, and use the latter precision profile to estimate the critical value and minimum detectable value of the net state variable.
The methods described ISO 11843-5:2008 are useful for checking the detection of a certain substance by various types of measurement equipment to which ISO 11843-2 cannot be applied. Included are assays of persistent organic pollutants (POPs) in the environment, such as dioxins, pesticides and hormone-like chemicals, by competitive ELISA (enzyme-linked immunosorbent assay), and tests of bacterial endotoxins that induce hyperthermia in humans.
The definition and applicability of the critical value and minimum detectable value of the net state variable are described in ISO 11843-1 and ISO 11843-2. ISO 11843-5:2008 extends the concepts in ISO 11843-2 to the cases of non-linear calibration. Examples are provided.
Edition
1
Published Date
2008-05-22
Status
PUBLISHED
Pages
15
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 11843-5:2008 is concerned with calibration functions that are either linear or non-linear. It specifies basic methods to construct a precision profile for the response variable, namely a description of the standard deviation or coefficient of variation of the response variable as a function of the net state variable, transform this precision profile into a precision profile for the net state variable in conjunction with the calibration function, and use the latter precision profile to estimate the critical value and minimum detectable value of the net state variable.
The methods described ISO 11843-5:2008 are useful for checking the detection of a certain substance by various types of measurement equipment to which ISO 11843-2 cannot be applied. Included are assays of persistent organic pollutants (POPs) in the environment, such as dioxins, pesticides and hormone-like chemicals, by competitive ELISA (enzyme-linked immunosorbent assay), and tests of bacterial endotoxins that induce hyperthermia in humans.
The definition and applicability of the critical value and minimum detectable value of the net state variable are described in ISO 11843-1 and ISO 11843-2. ISO 11843-5:2008 extends the concepts in ISO 11843-2 to the cases of non-linear calibration. Examples are provided.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 3301:1975 Statistical interpretation of data – Comparison of two means in the case of paired observations
CDN $86.00 Add to cart -

ISO 28596:2022 Sampling procedures for inspection by attributes – Two-stage sampling plans for auditing and for inspection under prior information
CDN $352.00 Add to cart -

ISO 2859:2020 Sampling procedures for inspection by attributes – Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection
CDN $382.00 Add to cart -

ISO 10017:2021 Quality management – Guidance on statistical techniques for ISO 9001:2015
CDN $310.00 Add to cart







