ISO 12010:2019
ISO 12010:2019 Water quality – Determination of short-chain polychlorinated alkanes (SCCP) in water – Method using gas chromatography-mass spectrometry (GC-MS) and negative-ion chemical ionization (NCI)
CDN $312.00
Description
This document specifies a method for the quantitative determination of the sum of short-chain polychlorinated n-alkanes also known as short-chain polychlorinated paraffins (SCCPs) in the carbon bond range n-C10 to n-C13 inclusive, in mixtures with chlorine mass fractions (“contents”) between 50 % and 67 %, including approximately 6 000 of approximately 8 000 congeners.
This method is applicable to the determination of the sum of SCCPs in unfiltered surface water, ground water, drinking water and waste water using gas chromatography-mass spectrometry with electron capture negative ionization (GC-ECNI-MS).
Depending on the capability of the GC-ECNI-MS instrument, the concentration range of the method is from 0,1 µg/l or lower to 10 µg/l. Depending on the waste water matrix, the lowest detectable concentration is estimated to be > 0,1 µg/l. The data of the interlaboratory trial concerning this method are given in Annex I.
Edition
2
Published Date
2019-03-01
Status
PUBLISHED
Pages
42
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a method for the quantitative determination of the sum of short-chain polychlorinated n-alkanes also known as short-chain polychlorinated paraffins (SCCPs) in the carbon bond range n-C10 to n-C13 inclusive, in mixtures with chlorine mass fractions ("contents") between 50 % and 67 %, including approximately 6 000 of approximately 8 000 congeners.
This method is applicable to the determination of the sum of SCCPs in unfiltered surface water, ground water, drinking water and waste water using gas chromatography-mass spectrometry with electron capture negative ionization (GC-ECNI-MS).
Depending on the capability of the GC-ECNI-MS instrument, the concentration range of the method is from 0,1 µg/l or lower to 10 µg/l. Depending on the waste water matrix, the lowest detectable concentration is estimated to be > 0,1 µg/l. The data of the interlaboratory trial concerning this method are given in Annex I.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 22478:2006 Water quality – Determination of certain explosives and related compounds – Method using high-performance liquid chromatography (HPLC) with UV detection
CDN $233.00 Add to cart -

ISO 16265:2009 Water quality – Determination of the methylene blue active substances (MBAS) index – Method using continuous flow analysis (CFA)
CDN $115.00 Add to cart -

ISO 15680:2003 Water quality – Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption
CDN $273.00 Add to cart -

ISO 6468:1996 Water quality – Determination of certain organochlorine insecticides, polychlorinated biphenyls and chlorobenzenes – Gas chromatographic method after liquid-liquid extraction
CDN $233.00 Add to cart