Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 12110:2013

ISO 12110:2013 Metallic materials – Fatigue testing – Variable amplitude fatigue testing – Part 1: General principles, test method and reporting requirements

CDN $233.00

SKU: 69635296d1fb Category:

Description

ISO 12110-1:2013 establishes general principles for fatigue testing of laboratory specimens under a sequence of cycles the amplitude of which varies from cycle to cycle.

This sequence of cycles is called loading time history (see 3.7) and is usually derived from loading measurements performed on components or structures submitted to true service loadings.

Detailed description of service loads recording is relevant to each laboratory or industrial sector and is therefore outside the scope of ISO 12110-1:2013.

The aim of the two parts of ISO 12110 is to set requirements and give some guidance on how to perform a variable amplitude fatigue test in order to produce consistent results for comparison purposes taking into account the typical scatter of fatigue data. Achieving this should help designers to correlate models and experimental data obtained from various sources.

Since ISO 12110-1:2013 involves mainly loading time histories and control signal generation, one expects it might be applied to strain or fatigue crack growth rate controlled loading conditions as well as to force-controlled loading conditions. This is theoretically true but precautions may be taken when applying this document to loading modes other than force-controlled loading mode.

ISO 12110-1:2013 relates to variable amplitude loading under force control mode which corresponds to most of the variable amplitude fatigue tests performed worldwide at the date of publication.

ISO 12110-1:2013 applies to the single actuator loading mode which corresponds to uniaxial loading in many cases.

The variable amplitude loading time histories referred in this document are deterministic; that is why ISO 12110-1:2013 deals with variable amplitude loading instead of random loading.

The following issues are not within the scope of ISO 12110-1:2013 and therefore will not be addressed: constant amplitude tests with isolated overloads or underloads; tests on large components or structures;environmental effects like corrosion, creep linked to temperature/time interactions leading to frequency and waveform effects; multiaxial loading.

Edition

1

Published Date

2013-06-25

Status

PUBLISHED

Pages

24

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 12110-1:2013 establishes general principles for fatigue testing of laboratory specimens under a sequence of cycles the amplitude of which varies from cycle to cycle.

This sequence of cycles is called loading time history (see 3.7) and is usually derived from loading measurements performed on components or structures submitted to true service loadings.

Detailed description of service loads recording is relevant to each laboratory or industrial sector and is therefore outside the scope of ISO 12110-1:2013.

The aim of the two parts of ISO 12110 is to set requirements and give some guidance on how to perform a variable amplitude fatigue test in order to produce consistent results for comparison purposes taking into account the typical scatter of fatigue data. Achieving this should help designers to correlate models and experimental data obtained from various sources.

Since ISO 12110-1:2013 involves mainly loading time histories and control signal generation, one expects it might be applied to strain or fatigue crack growth rate controlled loading conditions as well as to force-controlled loading conditions. This is theoretically true but precautions may be taken when applying this document to loading modes other than force-controlled loading mode.

ISO 12110-1:2013 relates to variable amplitude loading under force control mode which corresponds to most of the variable amplitude fatigue tests performed worldwide at the date of publication.

ISO 12110-1:2013 applies to the single actuator loading mode which corresponds to uniaxial loading in many cases.

The variable amplitude loading time histories referred in this document are deterministic; that is why ISO 12110-1:2013 deals with variable amplitude loading instead of random loading.

The following issues are not within the scope of ISO 12110-1:2013 and therefore will not be addressed: constant amplitude tests with isolated overloads or underloads; tests on large components or structures;environmental effects like corrosion, creep linked to temperature/time interactions leading to frequency and waveform effects; multiaxial loading.

Previous Editions