Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 12176:2008

ISO 12176:2008 Plastics pipes and fittings – Equipment for fusion jointing polyethylene systems – Part 2: Electrofusion

CDN $251.00

Description

ISO 12176-2:2008 specifies performance requirements for electrofusion control units for use with polyethylene (PE) electrofusion fittings for the supply of gaseous fuels or for the conveyance of water for human consumption, including raw water prior to treatment and for the conveyance of water for general purpose or other fluids.

The control units are divided into three input voltage classes: SVLV [safety, very low voltage (up to 50 V)], LV [low voltage (50 V to 250 V)] and HV [higher voltage (250 V to 400 V)].

ISO 12176-2:2008 is applicable to electrofusion control units designed for use in the construction of joints between PE pipes and fittings conforming to International Standards for the supply of gaseous fuels or for the conveyance of water, where the normal operating temperature of the control unit is in the range -10 °C to + 40 °C. If temperatures outside this range are expected, suitable operating limits are subject to agreement between manufacturer and purchaser.

ISO 12176-2:2008 is applicable to control units with current or voltage control for fitting systems based on standard resistance wire heating technology.

Edition

2

Published Date

2008-06-03

Status

PUBLISHED

Pages

19

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 12176-2:2008 specifies performance requirements for electrofusion control units for use with polyethylene (PE) electrofusion fittings for the supply of gaseous fuels or for the conveyance of water for human consumption, including raw water prior to treatment and for the conveyance of water for general purpose or other fluids.

The control units are divided into three input voltage classes: SVLV [safety, very low voltage (up to 50 V)], LV [low voltage (50 V to 250 V)] and HV [higher voltage (250 V to 400 V)].

ISO 12176-2:2008 is applicable to electrofusion control units designed for use in the construction of joints between PE pipes and fittings conforming to International Standards for the supply of gaseous fuels or for the conveyance of water, where the normal operating temperature of the control unit is in the range -10 °C to + 40 °C. If temperatures outside this range are expected, suitable operating limits are subject to agreement between manufacturer and purchaser.

ISO 12176-2:2008 is applicable to control units with current or voltage control for fitting systems based on standard resistance wire heating technology.

Previous Editions

Can’t find what you are looking for?